Kabeltværsnit for 1000 Ampere ved 400 Meter (230V)
Beregning af kabeltværsnit (mm²), spændingsfald og sikringsstørrelse efter dansk standard DS/HD 60364 for 1000 A over 400 m ved 230V.
Copper Cable (≤3% Drop)7× 400 mm²Drop: 6.11V (2.66%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 70.6V (30.7%)
Voltage at Load223.9 VLine Loss: 6114.3 W
Max Power & Breaker230.0 kW1000A MCB/MCCB
IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 1000A at 400m
| Cross-Section (mm²) | Cu Ampacity | Al Ampacity | Cu Voltage Drop | Load Voltage | Al Voltage Drop | Power Loss | Status |
|---|---|---|---|---|---|---|---|
| 1.5 mm² | 16 A | 12 A | 11413.33 V (4962.32%) | 0.0 V | 18826.67 V (8185.51%) | 11413333.3 W | Drop High |
| 2.5 mm² | 24 A | 18 A | 6848.0 V (2977.39%) | 0.0 V | 11296.0 V (4911.3%) | 6848000.0 W | Drop High |
| 4 mm² | 32 A | 25 A | 4280.0 V (1860.87%) | 0.0 V | 7060.0 V (3069.57%) | 4280000.0 W | Drop High |
| 6 mm² | 41 A | 32 A | 2853.33 V (1240.58%) | 0.0 V | 4706.67 V (2046.38%) | 2853333.3 W | Drop High |
| 10 mm² | 57 A | 44 A | 1712.0 V (744.35%) | 0.0 V | 2824.0 V (1227.83%) | 1712000.0 W | Drop High |
| 16 mm² | 76 A | 59 A | 1070.0 V (465.22%) | 0.0 V | 1765.0 V (767.39%) | 1070000.0 W | Drop High |
| 25 mm² | 101 A | 78 A | 684.8 V (297.74%) | 0.0 V | 1129.6 V (491.13%) | 684800.0 W | Drop High |
| 35 mm² | 125 A | 97 A | 489.14 V (212.67%) | 0.0 V | 806.86 V (350.81%) | 489142.9 W | Drop High |
| 50 mm² | 151 A | 118 A | 342.4 V (148.87%) | 0.0 V | 564.8 V (245.57%) | 342400.0 W | Drop High |
| 70 mm² | 192 A | 150 A | 244.57 V (106.34%) | 0.0 V | 403.43 V (175.4%) | 244571.4 W | Drop High |
| 95 mm² | 232 A | 181 A | 180.21 V (78.35%) | 49.8 V | 297.26 V (129.24%) | 180210.5 W | Drop High |
| 120 mm² | 269 A | 210 A | 142.67 V (62.03%) | 87.3 V | 235.33 V (102.32%) | 142666.7 W | Drop High |
| 150 mm² | 309 A | 241 A | 114.13 V (49.62%) | 115.9 V | 188.27 V (81.86%) | 114133.3 W | Drop High |
| 185 mm² | 353 A | 275 A | 92.54 V (40.24%) | 137.5 V | 152.65 V (66.37%) | 92540.5 W | Drop High |
| 240 mm² | 415 A | 324 A | 71.33 V (31.01%) | 158.7 V | 117.67 V (51.16%) | 71333.3 W | Drop High |
| 300 mm² | 477 A | 372 A | 57.07 V (24.81%) | 172.9 V | 94.13 V (40.93%) | 57066.7 W | Drop High |
| 400 mm² | 570 A | 445 A | 42.8 V (18.61%) | 187.2 V | 70.6 V (30.7%) | 42800.0 W | Drop High |
FAQ — Kabeltværsnit for 1000 Ampere ved 400 Meter (230V)
Hvilket kabeltværsnit kræves til 1000A ved 400 meter (230V)?
Til 1000 Ampere over 400 meter ved 230V anbefales 7× 400 mm² kobberkabel (spændingsfald 6.11V / 2.66%).
Hvor mange kW svarer 1000A ved 230V til?
Det svarer til 230.0 kW med en anbefalet sikring på 1000A.
Related Lengths & Currents (230V)
1000A · 5m (230V)1000A · 10m (230V)1000A · 15m (230V)1000A · 20m (230V)1000A · 25m (230V)1000A · 30m (230V)1000A · 35m (230V)1000A · 40m (230V)1000A · 45m (230V)1000A · 50m (230V)1000A · 60m (230V)1000A · 70m (230V)10A · 400m (230V)16A · 400m (230V)20A · 400m (230V)25A · 400m (230V)32A · 400m (230V)40A · 400m (230V)50A · 400m (230V)63A · 400m (230V)80A · 400m (230V)100A · 400m (230V)125A · 400m (230V)160A · 400m (230V)200A · 400m (230V)