Kabelquerschnitt für 475 Ampere bei 400 Meter (230V)

Berechnung des erforderlichen Leiterquerschnitts (mm²) und des Spannungsfalls nach DIN VDE 0100-520 / IEC 60364 für 475 A über 400 m einfache Leitungslänge bei 230V.

Copper Cable (≤3% Drop)3× 400 mm²Drop: 6.78V (2.95%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 33.53V (14.58%)
Voltage at Load223.2 VLine Loss: 3218.9 W
Max Power & Breaker109.25 kW500A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 475A at 400m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A5421.33 V (2357.1%)0.0 V8942.67 V (3888.12%)2575133.3 WDrop High
2.5 mm²24 A18 A3252.8 V (1414.26%)0.0 V5365.6 V (2332.87%)1545080.0 WDrop High
4 mm²32 A25 A2033.0 V (883.91%)0.0 V3353.5 V (1458.04%)965675.0 WDrop High
6 mm²41 A32 A1355.33 V (589.28%)0.0 V2235.67 V (972.03%)643783.3 WDrop High
10 mm²57 A44 A813.2 V (353.57%)0.0 V1341.4 V (583.22%)386270.0 WDrop High
16 mm²76 A59 A508.25 V (220.98%)0.0 V838.38 V (364.51%)241418.7 WDrop High
25 mm²101 A78 A325.28 V (141.43%)0.0 V536.56 V (233.29%)154508.0 WDrop High
35 mm²125 A97 A232.34 V (101.02%)0.0 V383.26 V (166.63%)110362.9 WDrop High
50 mm²151 A118 A162.64 V (70.71%)67.4 V268.28 V (116.64%)77254.0 WDrop High
70 mm²192 A150 A116.17 V (50.51%)113.8 V191.63 V (83.32%)55181.4 WDrop High
95 mm²232 A181 A85.6 V (37.22%)144.4 V141.2 V (61.39%)40660.0 WDrop High
120 mm²269 A210 A67.77 V (29.46%)162.2 V111.78 V (48.6%)32189.2 WDrop High
150 mm²309 A241 A54.21 V (23.57%)175.8 V89.43 V (38.88%)25751.3 WDrop High
185 mm²353 A275 A43.96 V (19.11%)186.0 V72.51 V (31.53%)20879.5 WDrop High
240 mm²415 A324 A33.88 V (14.73%)196.1 V55.89 V (24.3%)16094.6 WDrop High
300 mm²477 A372 A27.11 V (11.79%)202.9 V44.71 V (19.44%)12875.7 WDrop High
400 mm²570 A445 A20.33 V (8.84%)209.7 V33.53 V (14.58%)9656.7 WDrop High

FAQ — Kabelquerschnitt für 475 Ampere bei 400 Meter (230V)

Welcher Kabelquerschnitt wird für 475A bei 400m (230V) benötigt?

Für 475 Ampere über 400 Meter bei 230V wird ein Kupferkabel von 3× 400 mm² empfohlen, um den Spannungsfall unter 3% (6.78V bzw. 2.95%) zu halten.

Wie hoch ist die maximale Leistung bei 475A und 230V?

Die übertragbare Leistung beträgt 109.25 kW bei einer empfohlenen Absicherung von 500A.