🚗 EV Charging Time · NEC Article 625 · IEC 61851 Wallbox Sizing

58 kWh EV Battery Charging Time on 19.2 kW (240V 80A Max Level 2 AC)

Real-world charging duration (10–80%, 20–80%, and 0–100%), range added per hour, charging cost, and electrical circuit breaker sizing.

10% to 80% Charge Time2h 21m20%–80%: 2h 01m
Full 0% to 100% Time3h 26mGrid Energy: 64.4 kWh
Driving Range Added / Hour+98.7 km/h+61.3 miles / hour
Circuit Breaker Required100A (NEC)80.0A @ 240V (1P)

Charging Time & Electrical Specification Table (58 kWh @ 19.2 kW)

EV Battery Usable Capacity58 kWh
Charger Output Rating19.2 kW (240V 80A Max Level 2 AC)
10% to 80% Charging Time (Daily / Highway Optimal)2h 21m (2.35 hours)
20% to 80% Charging Time2h 01m (2.01 hours)
0% to 100% Full Charge Time (with BMS Tapering)3h 26m (3.43 hours)
Estimated Full Charge Cost (US / Germany / Sweden)$11.27 (US) · €21.9 (DE) · 106.26 kr (SE)
Continuous Current Draw & Breaker80.0 A @ 240V (1-Phase) → 100A NEC / 80A IEC Breaker

Frequently Asked Questions

How long does it take to charge a 58 kWh EV battery at 19.2 kW?

Charging a 58 kWh electric vehicle battery from 10% to 80% on a 19.2 kW (240V 80A Max Level 2 AC) takes approximately 2h 21m (or 3h 26m for a full 0% to 100% charge including charger efficiency and BMS tapering).

What breaker size is required for a 19.2 kW EV charger?

At 240V (1-Phase), a 19.2 kW charger draws 80.0A continuously, requiring a 100A breaker under US NEC 625.41 (125% continuous load rule) or a 80A breaker under European IEC/NEK standards.