Heat Pump Sizing for 148 m² (1,593 sq ft) — Nordic / Scandinavia (-20°C Design, SE/NO/FI/DK)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump17.6 kW60,054 BTU/h (5.0 Tons)
Annual Electricity Usage12,992 kWh/yrDelivers 44,174 kWh Heat (SCOP 3.4)
Savings vs Direct Electric31,182 kWh/yrSpecific Load: 114.8 W/m²
Electrical Circuit (230V)40 A BreakerPeak Compressor Input: 6.77 kW
Thermal & Electrical Specification Table (148 m² / 1,593 sq ft)
| Heated Floor Area | 148 m² (1,593 sq ft) |
| Climate Zone & Design Outdoor Temp | Nordic / Scandinavia (-20°C Design, SE/NO/FI/DK) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (114.8 W/m² Peak) |
| Peak Space Heating Load | 16.99 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 17.6 kW (60,054 BTU/h · 5.0 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 3.4 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 44,174 kWh Heat → 12,992 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 148 m² (1593 sq ft) house?
For a 148 m² (1593 sq ft) building with Older Uninsulated Building (85 W/m² Base) in Nordic / Scandinavia (-20°C Design, SE/NO/FI/DK), the peak space heating load is 16.99 kW (114.8 W/m²). Including domestic hot water allowance, a 17.6 kW (60,054 BTU/h / 5.0 Ton) heat pump is recommended.
How many kWh of electricity does a 17.6 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 3.4 over 2600 full-load equivalent heating hours, the heat pump consumes approximately 12,992 kWh of electricity per year to deliver 44,174 kWh of heat — saving 31,182 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
60 m² (646 ft²) Heat Pump80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump250 m² (2691 ft²) Heat Pump300 m² (3229 ft²) Heat Pump148 m² in Central Europe / DACH148 m² in UK & Temperate Maritime148 m² in US North & Canada Cold148 m² in US Sunbelt & Mediterranean148 m² in Australia & Mild APAC