Heat Pump Sizing for 170 m² (1,830 sq ft) — UK & Temperate Maritime (-5°C Design, UK/IE/NZ)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump14.3 kW48,794 BTU/h (4.07 Tons)
Annual Electricity Usage6,032 kWh/yrDelivers 24,732 kWh Heat (SCOP 4.1)
Savings vs Direct Electric18,700 kWh/yrSpecific Load: 80.8 W/m²
Electrical Circuit (230V)25 A BreakerPeak Compressor Input: 4.33 kW
Thermal & Electrical Specification Table (170 m² / 1,830 sq ft)
| Heated Floor Area | 170 m² (1,830 sq ft) |
| Climate Zone & Design Outdoor Temp | UK & Temperate Maritime (-5°C Design, UK/IE/NZ) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (80.8 W/m² Peak) |
| Peak Space Heating Load | 13.74 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 14.3 kW (48,794 BTU/h · 4.07 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 4.1 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 24,732 kWh Heat → 6,032 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 170 m² (1830 sq ft) house?
For a 170 m² (1830 sq ft) building with Older Uninsulated Building (85 W/m² Base) in UK & Temperate Maritime (-5°C Design, UK/IE/NZ), the peak space heating load is 13.74 kW (80.8 W/m²). Including domestic hot water allowance, a 14.3 kW (48,794 BTU/h / 4.07 Ton) heat pump is recommended.
How many kWh of electricity does a 14.3 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 4.1 over 1800 full-load equivalent heating hours, the heat pump consumes approximately 6,032 kWh of electricity per year to deliver 24,732 kWh of heat — saving 18,700 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
60 m² (646 ft²) Heat Pump80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump250 m² (2691 ft²) Heat Pump300 m² (3229 ft²) Heat Pump170 m² in Nordic / Scandinavia170 m² in Central Europe / DACH170 m² in US North & Canada Cold170 m² in US Sunbelt & Mediterranean170 m² in Australia & Mild APAC