❄️ Heat Pump & HVAC Thermal Load · EN 12831 & ACCA Manual J Reference

Heat Pump Sizing for 44 m² (474 sq ft) — Central Europe / DACH (-12°C Design, DE/CH/AT/NL)

Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.

Recommended Heat Pump2.4 kW8,189 BTU/h (0.68 Tons)
Annual Electricity Usage978 kWh/yrDelivers 3,717 kWh Heat (SCOP 3.8)
Savings vs Direct Electric2,739 kWh/yrSpecific Load: 40.2 W/m²
Electrical Circuit (230V)6 A BreakerPeak Compressor Input: 0.8 kW

Thermal & Electrical Specification Table (44 m² / 474 sq ft)

Heated Floor Area44 m² (474 sq ft)
Climate Zone & Design Outdoor TempCentral Europe / DACH (-12°C Design, DE/CH/AT/NL)
Building Insulation EnvelopeModern / New Build Insulation (35 W/m² Base) (40.2 W/m² Peak)
Peak Space Heating Load1.77 kW Thermal
Recommended Heat Pump Output (Incl. DHW)2.4 kW (8,189 BTU/h · 0.68 Tons)
Seasonal Coefficient of Performance (SCOP)3.8 (340%–450% Seasonal Efficiency)
Annual Heat Demand vs Electricity Consumed3,717 kWh Heat → 978 kWh Electricity

Frequently Asked Questions

What kW size heat pump do I need for a 44 m² (474 sq ft) house?

For a 44 m² (474 sq ft) building with Modern / New Build Insulation (35 W/m² Base) in Central Europe / DACH (-12°C Design, DE/CH/AT/NL), the peak space heating load is 1.77 kW (40.2 W/m²). Including domestic hot water allowance, a 2.4 kW (8,189 BTU/h / 0.68 Ton) heat pump is recommended.

How many kWh of electricity does a 2.4 kW heat pump use per year?

With a Seasonal Coefficient of Performance (SCOP) of 3.8 over 2100 full-load equivalent heating hours, the heat pump consumes approximately 978 kWh of electricity per year to deliver 3,717 kWh of heat — saving 2,739 kWh/year compared to direct electric radiators.