Heat Pump Sizing for 60 m² (646 sq ft) — US North & Canada Cold (-18°C Design, NY/IL/MI/ON)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump7.2 kW24,567 BTU/h (2.05 Tons)
Annual Electricity Usage4,546 kWh/yrDelivers 15,912 kWh Heat (SCOP 3.5)
Savings vs Direct Electric11,366 kWh/yrSpecific Load: 110.5 W/m²
Electrical Circuit (230V)15 A BreakerPeak Compressor Input: 2.67 kW
Thermal & Electrical Specification Table (60 m² / 646 sq ft)
| Heated Floor Area | 60 m² (646 sq ft) |
| Climate Zone & Design Outdoor Temp | US North & Canada Cold (-18°C Design, NY/IL/MI/ON) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (110.5 W/m² Peak) |
| Peak Space Heating Load | 6.63 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 7.2 kW (24,567 BTU/h · 2.05 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 3.5 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 15,912 kWh Heat → 4,546 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 60 m² (646 sq ft) house?
For a 60 m² (646 sq ft) building with Older Uninsulated Building (85 W/m² Base) in US North & Canada Cold (-18°C Design, NY/IL/MI/ON), the peak space heating load is 6.63 kW (110.5 W/m²). Including domestic hot water allowance, a 7.2 kW (24,567 BTU/h / 2.05 Ton) heat pump is recommended.
How many kWh of electricity does a 7.2 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 3.5 over 2400 full-load equivalent heating hours, the heat pump consumes approximately 4,546 kWh of electricity per year to deliver 15,912 kWh of heat — saving 11,366 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump250 m² (2691 ft²) Heat Pump300 m² (3229 ft²) Heat Pump60 m² in Nordic / Scandinavia60 m² in Central Europe / DACH60 m² in UK & Temperate Maritime60 m² in US Sunbelt & Mediterranean60 m² in Australia & Mild APAC