100 Amp Cable Size at 600 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 100 A over 600 m (1968.5 ft).

Copper Cable (≤3% Drop)9× 400 mm²Drop: 0.71V (2.97%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 10.59V (44.12%)
Voltage at Load23.3 VLine Loss: 71.3 W
Max Power & Breaker2.4 kW100A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 100A at 600m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A1712.0 V (7133.33%)0.0 V2824.0 V (11766.67%)171200.0 WDrop High
2.5 mm²24 A18 A1027.2 V (4280.0%)0.0 V1694.4 V (7060.0%)102720.0 WDrop High
4 mm²32 A25 A642.0 V (2675.0%)0.0 V1059.0 V (4412.5%)64200.0 WDrop High
6 mm²41 A32 A428.0 V (1783.33%)0.0 V706.0 V (2941.67%)42800.0 WDrop High
10 mm²57 A44 A256.8 V (1070.0%)0.0 V423.6 V (1765.0%)25680.0 WDrop High
16 mm²76 A59 A160.5 V (668.75%)0.0 V264.75 V (1103.12%)16050.0 WDrop High
25 mm²101 A78 A102.72 V (428.0%)0.0 V169.44 V (706.0%)10272.0 WDrop High
35 mm²125 A97 A73.37 V (305.71%)0.0 V121.03 V (504.29%)7337.1 WDrop High
50 mm²151 A118 A51.36 V (214.0%)0.0 V84.72 V (353.0%)5136.0 WDrop High
70 mm²192 A150 A36.69 V (152.86%)0.0 V60.51 V (252.14%)3668.6 WDrop High
95 mm²232 A181 A27.03 V (112.63%)0.0 V44.59 V (185.79%)2703.2 WDrop High
120 mm²269 A210 A21.4 V (89.17%)2.6 V35.3 V (147.08%)2140.0 WDrop High
150 mm²309 A241 A17.12 V (71.33%)6.9 V28.24 V (117.67%)1712.0 WDrop High
185 mm²353 A275 A13.88 V (57.84%)10.1 V22.9 V (95.41%)1388.1 WDrop High
240 mm²415 A324 A10.7 V (44.58%)13.3 V17.65 V (73.54%)1070.0 WDrop High
300 mm²477 A372 A8.56 V (35.67%)15.4 V14.12 V (58.83%)856.0 WDrop High
400 mm²570 A445 A6.42 V (26.75%)17.6 V10.59 V (44.12%)642.0 WDrop High

FAQ — 100 Amp Cable Size at 600 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 100A at 600 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 9× 400 mm² copper cable for 100A over 600m at 24V (voltage drop: 0.71V or 2.97%).

What is the power capacity of 100A at 24V?

At unity power factor, 100A at 24V supports 2.4 kW with a standard 100A circuit breaker.