900 Amp Cable Size at 300 Meters (48V DC (LiFePO4 Battery Bank / Telecom))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 900 A over 300 m (984.3 ft).

Copper Cable (≤3% Drop)21× 400 mm²Drop: 1.38V (2.87%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 47.65V (99.28%)
Voltage at Load46.6 VLine Loss: 1238.1 W
Max Power & Breaker43.2 kW1000A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 900A at 300m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A7704.0 V (16050.0%)0.0 V12708.0 V (26475.0%)6933600.0 WDrop High
2.5 mm²24 A18 A4622.4 V (9630.0%)0.0 V7624.8 V (15885.0%)4160160.0 WDrop High
4 mm²32 A25 A2889.0 V (6018.75%)0.0 V4765.5 V (9928.12%)2600100.0 WDrop High
6 mm²41 A32 A1926.0 V (4012.5%)0.0 V3177.0 V (6618.75%)1733400.0 WDrop High
10 mm²57 A44 A1155.6 V (2407.5%)0.0 V1906.2 V (3971.25%)1040040.0 WDrop High
16 mm²76 A59 A722.25 V (1504.69%)0.0 V1191.38 V (2482.03%)650025.0 WDrop High
25 mm²101 A78 A462.24 V (963.0%)0.0 V762.48 V (1588.5%)416016.0 WDrop High
35 mm²125 A97 A330.17 V (687.86%)0.0 V544.63 V (1134.64%)297154.3 WDrop High
50 mm²151 A118 A231.12 V (481.5%)0.0 V381.24 V (794.25%)208008.0 WDrop High
70 mm²192 A150 A165.09 V (343.93%)0.0 V272.31 V (567.32%)148577.1 WDrop High
95 mm²232 A181 A121.64 V (253.42%)0.0 V200.65 V (418.03%)109477.9 WDrop High
120 mm²269 A210 A96.3 V (200.62%)0.0 V158.85 V (330.94%)86670.0 WDrop High
150 mm²309 A241 A77.04 V (160.5%)0.0 V127.08 V (264.75%)69336.0 WDrop High
185 mm²353 A275 A62.46 V (130.14%)0.0 V103.04 V (214.66%)56218.4 WDrop High
240 mm²415 A324 A48.15 V (100.31%)0.0 V79.42 V (165.47%)43335.0 WDrop High
300 mm²477 A372 A38.52 V (80.25%)9.5 V63.54 V (132.38%)34668.0 WDrop High
400 mm²570 A445 A28.89 V (60.19%)19.1 V47.65 V (99.28%)26001.0 WDrop High

FAQ — 900 Amp Cable Size at 300 Meters (48V DC (LiFePO4 Battery Bank / Telecom))

What mm² cable size is required for 900A at 300 meters (48V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 21× 400 mm² copper cable for 900A over 300m at 48V (voltage drop: 1.38V or 2.87%).

What is the power capacity of 900A at 48V?

At unity power factor, 900A at 48V supports 43.2 kW with a standard 1000A circuit breaker.