❄️ Heat Pump & HVAC Thermal Load · EN 12831 & ACCA Manual J Reference

Heat Pump Sizing for 216 m² (2,325 sq ft) — Australia & Mild APAC (Sydney/Melbourne/Tokyo)

Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.

Recommended Heat Pump6.6 kW22,520 BTU/h (1.88 Tons)
Annual Electricity Usage1,882 kWh/yrDelivers 8,470 kWh Heat (SCOP 4.5)
Savings vs Direct Electric6,588 kWh/yrSpecific Load: 28.0 W/m²
Electrical Circuit (230V)10 A BreakerPeak Compressor Input: 1.78 kW

Thermal & Electrical Specification Table (216 m² / 2,325 sq ft)

Heated Floor Area216 m² (2,325 sq ft)
Climate Zone & Design Outdoor TempAustralia & Mild APAC (Sydney/Melbourne/Tokyo)
Building Insulation EnvelopeModern / New Build Insulation (35 W/m² Base) (28.0 W/m² Peak)
Peak Space Heating Load6.05 kW Thermal
Recommended Heat Pump Output (Incl. DHW)6.6 kW (22,520 BTU/h · 1.88 Tons)
Seasonal Coefficient of Performance (SCOP)4.5 (340%–450% Seasonal Efficiency)
Annual Heat Demand vs Electricity Consumed8,470 kWh Heat → 1,882 kWh Electricity

Frequently Asked Questions

What kW size heat pump do I need for a 216 m² (2325 sq ft) house?

For a 216 m² (2325 sq ft) building with Modern / New Build Insulation (35 W/m² Base) in Australia & Mild APAC (Sydney/Melbourne/Tokyo), the peak space heating load is 6.05 kW (28.0 W/m²). Including domestic hot water allowance, a 6.6 kW (22,520 BTU/h / 1.88 Ton) heat pump is recommended.

How many kWh of electricity does a 6.6 kW heat pump use per year?

With a Seasonal Coefficient of Performance (SCOP) of 4.5 over 1400 full-load equivalent heating hours, the heat pump consumes approximately 1,882 kWh of electricity per year to deliver 8,470 kWh of heat — saving 6,588 kWh/year compared to direct electric radiators.