Heat Pump Sizing for 250 m² (2,691 sq ft) — Australia & Mild APAC (Sydney/Melbourne/Tokyo)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump17.6 kW60,054 BTU/h (5.0 Tons)
Annual Electricity Usage5,289 kWh/yrDelivers 23,800 kWh Heat (SCOP 4.5)
Savings vs Direct Electric18,511 kWh/yrSpecific Load: 68.0 W/m²
Electrical Circuit (230V)30 A BreakerPeak Compressor Input: 4.76 kW
Thermal & Electrical Specification Table (250 m² / 2,691 sq ft)
| Heated Floor Area | 250 m² (2,691 sq ft) |
| Climate Zone & Design Outdoor Temp | Australia & Mild APAC (Sydney/Melbourne/Tokyo) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (68.0 W/m² Peak) |
| Peak Space Heating Load | 17.0 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 17.6 kW (60,054 BTU/h · 5.0 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 4.5 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 23,800 kWh Heat → 5,289 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 250 m² (2691 sq ft) house?
For a 250 m² (2691 sq ft) building with Older Uninsulated Building (85 W/m² Base) in Australia & Mild APAC (Sydney/Melbourne/Tokyo), the peak space heating load is 17.0 kW (68.0 W/m²). Including domestic hot water allowance, a 17.6 kW (60,054 BTU/h / 5.0 Ton) heat pump is recommended.
How many kWh of electricity does a 17.6 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 4.5 over 1400 full-load equivalent heating hours, the heat pump consumes approximately 5,289 kWh of electricity per year to deliver 23,800 kWh of heat — saving 18,511 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
60 m² (646 ft²) Heat Pump80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump300 m² (3229 ft²) Heat Pump250 m² in Nordic / Scandinavia250 m² in Central Europe / DACH250 m² in UK & Temperate Maritime250 m² in US North & Canada Cold250 m² in US Sunbelt & Mediterranean