Heat Pump Sizing for 316 m² (3,401 sq ft) — Australia & Mild APAC (Sydney/Melbourne/Tokyo)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump22.1 kW75,408 BTU/h (6.28 Tons)
Annual Electricity Usage6,686 kWh/yrDelivers 30,086 kWh Heat (SCOP 4.5)
Savings vs Direct Electric23,400 kWh/yrSpecific Load: 68.0 W/m²
Electrical Circuit (230V)35 A BreakerPeak Compressor Input: 5.97 kW
Thermal & Electrical Specification Table (316 m² / 3,401 sq ft)
| Heated Floor Area | 316 m² (3,401 sq ft) |
| Climate Zone & Design Outdoor Temp | Australia & Mild APAC (Sydney/Melbourne/Tokyo) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (68.0 W/m² Peak) |
| Peak Space Heating Load | 21.49 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 22.1 kW (75,408 BTU/h · 6.28 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 4.5 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 30,086 kWh Heat → 6,686 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 316 m² (3401 sq ft) house?
For a 316 m² (3401 sq ft) building with Older Uninsulated Building (85 W/m² Base) in Australia & Mild APAC (Sydney/Melbourne/Tokyo), the peak space heating load is 21.49 kW (68.0 W/m²). Including domestic hot water allowance, a 22.1 kW (75,408 BTU/h / 6.28 Ton) heat pump is recommended.
How many kWh of electricity does a 22.1 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 4.5 over 1400 full-load equivalent heating hours, the heat pump consumes approximately 6,686 kWh of electricity per year to deliver 30,086 kWh of heat — saving 23,400 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
60 m² (646 ft²) Heat Pump80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump250 m² (2691 ft²) Heat Pump300 m² (3229 ft²) Heat Pump316 m² in Nordic / Scandinavia316 m² in Central Europe / DACH316 m² in UK & Temperate Maritime316 m² in US North & Canada Cold316 m² in US Sunbelt & Mediterranean