46 kVA to Amps at 120V Single-Phase AC

Exact current (Amps), real power (kW), apparent power (kVA), mechanical horsepower (HP), breaker rating, and conductor size for 46 kVA on a 120V Single-Phase AC circuit.

Line Current (0.85 PF)383.33 AAt 1.0 PF: 383.33 A
Active / Apparent Power39.1 kW46.0 kVA · 24.23 kVAR
Recommended Breaker500 A (NEC)400 A (IEC Nominal)
Recommended Copper Wire600 kcmilIEC Metric: 240 mm²

Engineering Breakdown for 46 kVA at 120V

Input Rating46 kVA (120V Single-Phase AC)
Amperage at 0.85 Power Factor (Industrial Motor/Transformer)383.33 Amps
Amperage at 1.00 Power Factor (Resistive Load)383.33 Amps
Real Power (kW / Watts)39.1 kW (39,100 W)
Apparent Power (kVA) & Reactive Power (kVAR)46.0 kVA / 24.23 kVAR
Equivalent Mechanical Horsepower (HP)52.43 HP
NEC 125% Continuous Circuit Breaker500 A
Minimum Copper Conductor (100 ft / 30 m, ≤3% Drop)600 kcmil (NEC) / 240 mm² (IEC)

Frequently Asked Questions

How many amps is 46 kVA at 120V (1-Phase)?

At 120V Single-Phase AC, 46 kVA equals 383.33 Amps at an industrial power factor of 0.85 (or 383.33 Amps at unity power factor 1.0).

What size breaker and wire is needed for 46 kVA at 120V?

For 383.33A continuous load, NEC requires a 125% rated breaker of 500A with 600 kcmil copper conductors, while IEC standard sizing uses a 400A breaker with 240 mm² copper cable.