⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

325 Amp Cable Size at 250 Meters (230V Single-Phase (IEC Europe / UK / AU))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 325 A over 250 m (820.2 ft).

Copper Cable (≤3% Drop)2× 400 mm²Drop: 4.34V (1.89%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 14.34V (6.24%)
Voltage at Load225.7 VLine Loss: 1412.8 W
Max Power & Breaker74.75 kW350A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 325A at 250m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A2318.33 V (1007.97%)0.0 V3824.17 V (1662.68%)753458.3 WDrop High
2.5 mm²24 A18 A1391.0 V (604.78%)0.0 V2294.5 V (997.61%)452075.0 WDrop High
4 mm²32 A25 A869.37 V (377.99%)0.0 V1434.06 V (623.51%)282546.9 WDrop High
6 mm²41 A32 A579.58 V (251.99%)0.0 V956.04 V (415.67%)188364.6 WDrop High
10 mm²57 A44 A347.75 V (151.2%)0.0 V573.62 V (249.4%)113018.7 WDrop High
16 mm²76 A59 A217.34 V (94.5%)12.7 V358.52 V (155.88%)70636.7 WDrop High
25 mm²101 A78 A139.1 V (60.48%)90.9 V229.45 V (99.76%)45207.5 WDrop High
35 mm²125 A97 A99.36 V (43.2%)130.6 V163.89 V (71.26%)32291.1 WDrop High
50 mm²151 A118 A69.55 V (30.24%)160.4 V114.72 V (49.88%)22603.8 WDrop High
70 mm²192 A150 A49.68 V (21.6%)180.3 V81.95 V (35.63%)16145.5 WDrop High
95 mm²232 A181 A36.61 V (15.92%)193.4 V60.38 V (26.25%)11896.7 WDrop High
120 mm²269 A210 A28.98 V (12.6%)201.0 V47.8 V (20.78%)9418.2 WDrop High
150 mm²309 A241 A23.18 V (10.08%)206.8 V38.24 V (16.63%)7534.6 WDrop High
185 mm²353 A275 A18.8 V (8.17%)211.2 V31.01 V (13.48%)6109.1 WDrop High
240 mm²415 A324 A14.49 V (6.3%)215.5 V23.9 V (10.39%)4709.1 WDrop High
300 mm²477 A372 A11.59 V (5.04%)218.4 V19.12 V (8.31%)3767.3 WDrop High
400 mm²570 A445 A8.69 V (3.78%)221.3 V14.34 V (6.24%)2825.5 W~ ≤5%

FAQ — 325 Amp Cable Size at 250 Meters (230V Single-Phase (IEC Europe / UK / AU))

What mm² cable size is required for 325A at 250 meters (230V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 2× 400 mm² copper cable for 325A over 250m at 230V (voltage drop: 4.34V or 1.89%).

What is the power capacity of 325A at 230V?

At unity power factor, 325A at 230V supports 74.75 kW with a standard 350A circuit breaker.