800 Amp Cable Size at 400 Meters (230V Single-Phase (IEC Europe / UK / AU))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 800 A over 400 m (1312.3 ft).

Copper Cable (≤3% Drop)5× 400 mm²Drop: 6.85V (2.98%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 56.48V (24.56%)
Voltage at Load223.2 VLine Loss: 5478.4 W
Max Power & Breaker184.0 kW800A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 800A at 400m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A9130.67 V (3969.86%)0.0 V15061.33 V (6548.41%)7304533.3 WDrop High
2.5 mm²24 A18 A5478.4 V (2381.91%)0.0 V9036.8 V (3929.04%)4382720.0 WDrop High
4 mm²32 A25 A3424.0 V (1488.7%)0.0 V5648.0 V (2455.65%)2739200.0 WDrop High
6 mm²41 A32 A2282.67 V (992.46%)0.0 V3765.33 V (1637.1%)1826133.3 WDrop High
10 mm²57 A44 A1369.6 V (595.48%)0.0 V2259.2 V (982.26%)1095680.0 WDrop High
16 mm²76 A59 A856.0 V (372.17%)0.0 V1412.0 V (613.91%)684800.0 WDrop High
25 mm²101 A78 A547.84 V (238.19%)0.0 V903.68 V (392.9%)438272.0 WDrop High
35 mm²125 A97 A391.31 V (170.14%)0.0 V645.49 V (280.65%)313051.4 WDrop High
50 mm²151 A118 A273.92 V (119.1%)0.0 V451.84 V (196.45%)219136.0 WDrop High
70 mm²192 A150 A195.66 V (85.07%)34.3 V322.74 V (140.32%)156525.7 WDrop High
95 mm²232 A181 A144.17 V (62.68%)85.8 V237.81 V (103.4%)115334.7 WDrop High
120 mm²269 A210 A114.13 V (49.62%)115.9 V188.27 V (81.86%)91306.7 WDrop High
150 mm²309 A241 A91.31 V (39.7%)138.7 V150.61 V (65.48%)73045.3 WDrop High
185 mm²353 A275 A74.03 V (32.19%)156.0 V122.12 V (53.1%)59225.9 WDrop High
240 mm²415 A324 A57.07 V (24.81%)172.9 V94.13 V (40.93%)45653.3 WDrop High
300 mm²477 A372 A45.65 V (19.85%)184.3 V75.31 V (32.74%)36522.7 WDrop High
400 mm²570 A445 A34.24 V (14.89%)195.8 V56.48 V (24.56%)27392.0 WDrop High

FAQ — 800 Amp Cable Size at 400 Meters (230V Single-Phase (IEC Europe / UK / AU))

What mm² cable size is required for 800A at 400 meters (230V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 5× 400 mm² copper cable for 800A over 400m at 230V (voltage drop: 6.85V or 2.98%).

What is the power capacity of 800A at 230V?

At unity power factor, 800A at 230V supports 184.0 kW with a standard 800A circuit breaker.