800 Amp Cable Size at 80 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 800 A over 80 m (262.5 ft).

Copper Cable (≤3% Drop)10× 400 mm²Drop: 0.68V (2.85%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 11.3V (47.07%)
Voltage at Load23.3 VLine Loss: 547.8 W
Max Power & Breaker19.2 kW800A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 800A at 80m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A1826.13 V (7608.89%)0.0 V3012.27 V (12551.11%)1460906.7 WDrop High
2.5 mm²24 A18 A1095.68 V (4565.33%)0.0 V1807.36 V (7530.67%)876544.0 WDrop High
4 mm²32 A25 A684.8 V (2853.33%)0.0 V1129.6 V (4706.67%)547840.0 WDrop High
6 mm²41 A32 A456.53 V (1902.22%)0.0 V753.07 V (3137.78%)365226.7 WDrop High
10 mm²57 A44 A273.92 V (1141.33%)0.0 V451.84 V (1882.67%)219136.0 WDrop High
16 mm²76 A59 A171.2 V (713.33%)0.0 V282.4 V (1176.67%)136960.0 WDrop High
25 mm²101 A78 A109.57 V (456.53%)0.0 V180.74 V (753.07%)87654.4 WDrop High
35 mm²125 A97 A78.26 V (326.1%)0.0 V129.1 V (537.9%)62610.3 WDrop High
50 mm²151 A118 A54.78 V (228.27%)0.0 V90.37 V (376.53%)43827.2 WDrop High
70 mm²192 A150 A39.13 V (163.05%)0.0 V64.55 V (268.95%)31305.1 WDrop High
95 mm²232 A181 A28.83 V (120.14%)0.0 V47.56 V (198.18%)23066.9 WDrop High
120 mm²269 A210 A22.83 V (95.11%)1.2 V37.65 V (156.89%)18261.3 WDrop High
150 mm²309 A241 A18.26 V (76.09%)5.7 V30.12 V (125.51%)14609.1 WDrop High
185 mm²353 A275 A14.81 V (61.69%)9.2 V24.42 V (101.77%)11845.2 WDrop High
240 mm²415 A324 A11.41 V (47.56%)12.6 V18.83 V (78.44%)9130.7 WDrop High
300 mm²477 A372 A9.13 V (38.04%)14.9 V15.06 V (62.76%)7304.5 WDrop High
400 mm²570 A445 A6.85 V (28.53%)17.2 V11.3 V (47.07%)5478.4 WDrop High

FAQ — 800 Amp Cable Size at 80 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 800A at 80 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 10× 400 mm² copper cable for 800A over 80m at 24V (voltage drop: 0.68V or 2.85%).

What is the power capacity of 800A at 24V?

At unity power factor, 800A at 24V supports 19.2 kW with a standard 800A circuit breaker.