900 Amp Cable Size at 600 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 900 A over 600 m (1968.5 ft).

Copper Cable (≤3% Drop)81× 400 mm²Drop: 0.71V (2.97%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 95.31V (397.12%)
Voltage at Load23.3 VLine Loss: 642.0 W
Max Power & Breaker21.6 kW1000A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 900A at 600m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A15408.0 V (64200.0%)0.0 V25416.0 V (105900.0%)13867200.0 WDrop High
2.5 mm²24 A18 A9244.8 V (38520.0%)0.0 V15249.6 V (63540.0%)8320320.0 WDrop High
4 mm²32 A25 A5778.0 V (24075.0%)0.0 V9531.0 V (39712.5%)5200200.0 WDrop High
6 mm²41 A32 A3852.0 V (16050.0%)0.0 V6354.0 V (26475.0%)3466800.0 WDrop High
10 mm²57 A44 A2311.2 V (9630.0%)0.0 V3812.4 V (15885.0%)2080080.0 WDrop High
16 mm²76 A59 A1444.5 V (6018.75%)0.0 V2382.75 V (9928.12%)1300050.0 WDrop High
25 mm²101 A78 A924.48 V (3852.0%)0.0 V1524.96 V (6354.0%)832032.0 WDrop High
35 mm²125 A97 A660.34 V (2751.43%)0.0 V1089.26 V (4538.57%)594308.6 WDrop High
50 mm²151 A118 A462.24 V (1926.0%)0.0 V762.48 V (3177.0%)416016.0 WDrop High
70 mm²192 A150 A330.17 V (1375.71%)0.0 V544.63 V (2269.29%)297154.3 WDrop High
95 mm²232 A181 A243.28 V (1013.68%)0.0 V401.31 V (1672.11%)218955.8 WDrop High
120 mm²269 A210 A192.6 V (802.5%)0.0 V317.7 V (1323.75%)173340.0 WDrop High
150 mm²309 A241 A154.08 V (642.0%)0.0 V254.16 V (1059.0%)138672.0 WDrop High
185 mm²353 A275 A124.93 V (520.54%)0.0 V206.08 V (858.65%)112436.8 WDrop High
240 mm²415 A324 A96.3 V (401.25%)0.0 V158.85 V (661.88%)86670.0 WDrop High
300 mm²477 A372 A77.04 V (321.0%)0.0 V127.08 V (529.5%)69336.0 WDrop High
400 mm²570 A445 A57.78 V (240.75%)0.0 V95.31 V (397.12%)52002.0 WDrop High

FAQ — 900 Amp Cable Size at 600 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 900A at 600 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 81× 400 mm² copper cable for 900A over 600m at 24V (voltage drop: 0.71V or 2.97%).

What is the power capacity of 900A at 24V?

At unity power factor, 900A at 24V supports 21.6 kW with a standard 1000A circuit breaker.