❄️ Heat Pump & HVAC Thermal Load · EN 12831 & ACCA Manual J Reference

Heat Pump Sizing for 32 m² (344 sq ft) — Central Europe / DACH (-12°C Design, DE/CH/AT/NL)

Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.

Recommended Heat Pump2.6 kW8,872 BTU/h (0.74 Tons)
Annual Electricity Usage1,116 kWh/yrDelivers 4,242 kWh Heat (SCOP 3.8)
Savings vs Direct Electric3,126 kWh/yrSpecific Load: 63.2 W/m²
Electrical Circuit (230V)6 A BreakerPeak Compressor Input: 0.87 kW

Thermal & Electrical Specification Table (32 m² / 344 sq ft)

Heated Floor Area32 m² (344 sq ft)
Climate Zone & Design Outdoor TempCentral Europe / DACH (-12°C Design, DE/CH/AT/NL)
Building Insulation EnvelopeStandard Double-Glazed Insulation (55 W/m² Base) (63.2 W/m² Peak)
Peak Space Heating Load2.02 kW Thermal
Recommended Heat Pump Output (Incl. DHW)2.6 kW (8,872 BTU/h · 0.74 Tons)
Seasonal Coefficient of Performance (SCOP)3.8 (340%–450% Seasonal Efficiency)
Annual Heat Demand vs Electricity Consumed4,242 kWh Heat → 1,116 kWh Electricity

Frequently Asked Questions

What kW size heat pump do I need for a 32 m² (344 sq ft) house?

For a 32 m² (344 sq ft) building with Standard Double-Glazed Insulation (55 W/m² Base) in Central Europe / DACH (-12°C Design, DE/CH/AT/NL), the peak space heating load is 2.02 kW (63.2 W/m²). Including domestic hot water allowance, a 2.6 kW (8,872 BTU/h / 0.74 Ton) heat pump is recommended.

How many kWh of electricity does a 2.6 kW heat pump use per year?

With a Seasonal Coefficient of Performance (SCOP) of 3.8 over 2100 full-load equivalent heating hours, the heat pump consumes approximately 1,116 kWh of electricity per year to deliver 4,242 kWh of heat — saving 3,126 kWh/year compared to direct electric radiators.