Heat Pump Sizing for 484 m² (5,210 sq ft) — US North & Canada Cold (-18°C Design, NY/IL/MI/ON)
Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.
Recommended Heat Pump54.1 kW184,597 BTU/h (15.38 Tons)
Annual Electricity Usage36,672 kWh/yrDelivers 128,352 kWh Heat (SCOP 3.5)
Savings vs Direct Electric91,680 kWh/yrSpecific Load: 110.5 W/m²
Electrical Circuit (230V)110 A BreakerPeak Compressor Input: 20.04 kW
Thermal & Electrical Specification Table (484 m² / 5,210 sq ft)
| Heated Floor Area | 484 m² (5,210 sq ft) |
| Climate Zone & Design Outdoor Temp | US North & Canada Cold (-18°C Design, NY/IL/MI/ON) |
| Building Insulation Envelope | Older Uninsulated Building (85 W/m² Base) (110.5 W/m² Peak) |
| Peak Space Heating Load | 53.48 kW Thermal |
| Recommended Heat Pump Output (Incl. DHW) | 54.1 kW (184,597 BTU/h · 15.38 Tons) |
| Seasonal Coefficient of Performance (SCOP) | 3.5 (340%–450% Seasonal Efficiency) |
| Annual Heat Demand vs Electricity Consumed | 128,352 kWh Heat → 36,672 kWh Electricity |
Frequently Asked Questions
What kW size heat pump do I need for a 484 m² (5210 sq ft) house?
For a 484 m² (5210 sq ft) building with Older Uninsulated Building (85 W/m² Base) in US North & Canada Cold (-18°C Design, NY/IL/MI/ON), the peak space heating load is 53.48 kW (110.5 W/m²). Including domestic hot water allowance, a 54.1 kW (184,597 BTU/h / 15.38 Ton) heat pump is recommended.
How many kWh of electricity does a 54.1 kW heat pump use per year?
With a Seasonal Coefficient of Performance (SCOP) of 3.5 over 2400 full-load equivalent heating hours, the heat pump consumes approximately 36,672 kWh of electricity per year to deliver 128,352 kWh of heat — saving 91,680 kWh/year compared to direct electric radiators.
Compare Other Home Sizes & Climate Zones
60 m² (646 ft²) Heat Pump80 m² (861 ft²) Heat Pump100 m² (1076 ft²) Heat Pump120 m² (1292 ft²) Heat Pump140 m² (1507 ft²) Heat Pump160 m² (1722 ft²) Heat Pump180 m² (1938 ft²) Heat Pump200 m² (2153 ft²) Heat Pump250 m² (2691 ft²) Heat Pump300 m² (3229 ft²) Heat Pump484 m² in Nordic / Scandinavia484 m² in Central Europe / DACH484 m² in UK & Temperate Maritime484 m² in US Sunbelt & Mediterranean484 m² in Australia & Mild APAC