200 Amp Wire Size at 800 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 200 A load over a 800 ft (243.8 m) one-way run.

Copper Wire (≤3% Drop)12× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.86%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 6.79V (56.62%)
Voltage at Load End11.7 VLoss: 0.34 V (68.7 W)
Power & Breaker (125%)2.4 kW250A Breaker Recommended

All AWG & kcmil Wire Gauges for 200 Amps at 800 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1003.5 V (8362.46%)0.0 V1655.3 V (13794.15%)200699.1 WDrop/Amp High
12 AWG3.31 mm²20 A630.6 V (5254.96%)0.0 V1040.19 V (8668.23%)126119.1 WDrop/Amp High
10 AWG5.26 mm²30 A396.82 V (3306.83%)0.0 V654.57 V (5454.72%)79363.9 WDrop/Amp High
8 AWG8.37 mm²50 A249.38 V (2078.13%)0.0 V411.35 V (3427.94%)49875.0 WDrop/Amp High
6 AWG13.3 mm²65 A156.94 V (1307.81%)0.0 V258.87 V (2157.28%)31387.5 WDrop/Amp High
4 AWG21.15 mm²85 A98.69 V (822.41%)0.0 V162.79 V (1356.59%)19737.8 WDrop/Amp High
3 AWG26.67 mm²100 A78.26 V (652.19%)0.0 V129.1 V (1075.81%)15652.6 WDrop/Amp High
2 AWG33.62 mm²115 A62.08 V (517.37%)0.0 V102.41 V (853.42%)12416.8 WDrop/Amp High
1 AWG42.41 mm²130 A49.22 V (410.14%)0.0 V81.18 V (676.53%)9843.3 WDrop/Amp High
1/0 AWG53.49 mm²150 A39.02 V (325.18%)0.0 V64.37 V (536.4%)7804.3 WDrop/Amp High
2/0 AWG67.43 mm²175 A30.95 V (257.96%)0.0 V51.06 V (425.51%)6190.9 WDrop/Amp High
3/0 AWG85.01 mm²200 A24.55 V (204.61%)0.0 V40.5 V (337.51%)4910.6 WDrop/Amp High
4/0 AWG107.2 mm²230 A19.47 V (162.26%)0.0 V32.12 V (267.65%)3894.2 WDrop/Amp High
250 kcmil126.7 mm²255 A16.47 V (137.28%)0.0 V27.17 V (226.45%)3294.8 WDrop/Amp High
300 kcmil152.0 mm²285 A13.73 V (114.43%)0.0 V22.65 V (188.76%)2746.4 WDrop/Amp High
350 kcmil177.3 mm²310 A11.77 V (98.1%)0.2 V19.42 V (161.83%)2354.5 WDrop/Amp High
400 kcmil202.7 mm²335 A10.3 V (85.81%)1.7 V16.99 V (141.55%)2059.5 WDrop/Amp High
500 kcmil253.4 mm²380 A8.24 V (68.64%)3.8 V13.59 V (113.23%)1647.4 WDrop/Amp High
600 kcmil304.0 mm²420 A6.87 V (57.22%)5.1 V11.33 V (94.38%)1373.2 WDrop/Amp High
750 kcmil380.0 mm²475 A5.49 V (45.77%)6.5 V9.06 V (75.5%)1098.6 WDrop/Amp High
1000 kcmil506.7 mm²545 A4.12 V (34.33%)7.9 V6.79 V (56.62%)823.9 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 200 amps at 800 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 200A load over 800 feet one-way at 12V (DC), you need 12× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.34V (2.86%) and delivers 11.7V at the load.

What size aluminum wire is required for 200 amps at 800 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 6.79V (56.62%).

What breaker size is needed for a 200A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (200A × 1.25 = 250.0A), which corresponds to a standard 250A circuit breaker.