⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

900 Amp Wire Size at 225 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 900 A load over a 225 ft (68.6 m) one-way run.

Copper Wire (≤3% Drop)15× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.9%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 8.6V (71.67%)
Voltage at Load End11.7 VLoss: 0.35 V (312.8 W)
Power & Breaker (125%)10.8 kW1200A Breaker Recommended

All AWG & kcmil Wire Gauges for 900 Amps at 225 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1270.05 V (10583.74%)0.0 V2094.99 V (17458.23%)1143044.0 WDrop/Amp High
12 AWG3.31 mm²20 A798.1 V (6650.81%)0.0 V1316.49 V (10970.73%)718287.4 WDrop/Amp High
10 AWG5.26 mm²30 A502.22 V (4185.21%)0.0 V828.44 V (6903.63%)452002.2 WDrop/Amp High
8 AWG8.37 mm²50 A315.62 V (2630.13%)0.0 V520.62 V (4338.48%)284053.9 WDrop/Amp High
6 AWG13.3 mm²65 A198.62 V (1655.2%)0.0 V327.64 V (2730.31%)178761.8 WDrop/Amp High
4 AWG21.15 mm²85 A124.9 V (1040.86%)0.0 V206.03 V (1716.93%)112412.8 WDrop/Amp High
3 AWG26.67 mm²100 A99.05 V (825.43%)0.0 V163.39 V (1361.57%)89146.3 WDrop/Amp High
2 AWG33.62 mm²115 A78.58 V (654.79%)0.0 V129.61 V (1080.1%)70717.8 WDrop/Amp High
1 AWG42.41 mm²130 A62.29 V (519.08%)0.0 V102.75 V (856.24%)56060.6 WDrop/Amp High
1/0 AWG53.49 mm²150 A49.39 V (411.56%)0.0 V81.47 V (678.88%)44448.1 WDrop/Amp High
2/0 AWG67.43 mm²175 A39.18 V (326.47%)0.0 V64.62 V (538.53%)35259.3 WDrop/Amp High
3/0 AWG85.01 mm²200 A31.08 V (258.96%)0.0 V51.26 V (427.16%)27967.7 WDrop/Amp High
4/0 AWG107.2 mm²230 A24.64 V (205.36%)0.0 V40.65 V (338.74%)22178.5 WDrop/Amp High
250 kcmil126.7 mm²255 A20.85 V (173.75%)0.0 V34.39 V (286.61%)18765.0 WDrop/Amp High
300 kcmil152.0 mm²285 A17.38 V (144.83%)0.0 V28.67 V (238.9%)15641.7 WDrop/Amp High
350 kcmil177.3 mm²310 A14.9 V (124.16%)0.0 V24.58 V (204.81%)13409.7 WDrop/Amp High
400 kcmil202.7 mm²335 A13.03 V (108.6%)0.0 V21.5 V (179.15%)11729.3 WDrop/Amp High
500 kcmil253.4 mm²380 A10.43 V (86.88%)1.6 V17.2 V (143.3%)9382.5 WDrop/Amp High
600 kcmil304.0 mm²420 A8.69 V (72.42%)3.3 V14.33 V (119.45%)7820.8 WDrop/Amp High
750 kcmil380.0 mm²475 A6.95 V (57.93%)5.0 V11.47 V (95.56%)6256.7 WDrop/Amp High
1000 kcmil506.7 mm²545 A5.21 V (43.45%)6.8 V8.6 V (71.67%)4692.2 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 900 amps at 225 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 900A load over 225 feet one-way at 12V (DC), you need 15× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.35V (2.9%) and delivers 11.7V at the load.

What size aluminum wire is required for 900 amps at 225 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 8.6V (71.67%).

What breaker size is needed for a 900A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (900A × 1.25 = 1125.0A), which corresponds to a standard 1200A circuit breaker.