1000 Amp Cable Size at 15 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 1000 A over 15 m (49.2 ft).

Copper Cable (≤3% Drop)3× 400 mm²Drop: 0.53V (2.23%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 2.65V (11.03%)
Voltage at Load23.5 VLine Loss: 535.0 W
Max Power & Breaker24.0 kW1000A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 1000A at 15m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A428.0 V (1783.33%)0.0 V706.0 V (2941.67%)428000.0 WDrop High
2.5 mm²24 A18 A256.8 V (1070.0%)0.0 V423.6 V (1765.0%)256800.0 WDrop High
4 mm²32 A25 A160.5 V (668.75%)0.0 V264.75 V (1103.12%)160500.0 WDrop High
6 mm²41 A32 A107.0 V (445.83%)0.0 V176.5 V (735.42%)107000.0 WDrop High
10 mm²57 A44 A64.2 V (267.5%)0.0 V105.9 V (441.25%)64200.0 WDrop High
16 mm²76 A59 A40.12 V (167.19%)0.0 V66.19 V (275.78%)40125.0 WDrop High
25 mm²101 A78 A25.68 V (107.0%)0.0 V42.36 V (176.5%)25680.0 WDrop High
35 mm²125 A97 A18.34 V (76.43%)5.7 V30.26 V (126.07%)18342.9 WDrop High
50 mm²151 A118 A12.84 V (53.5%)11.2 V21.18 V (88.25%)12840.0 WDrop High
70 mm²192 A150 A9.17 V (38.21%)14.8 V15.13 V (63.04%)9171.4 WDrop High
95 mm²232 A181 A6.76 V (28.16%)17.2 V11.15 V (46.45%)6757.9 WDrop High
120 mm²269 A210 A5.35 V (22.29%)18.6 V8.82 V (36.77%)5350.0 WDrop High
150 mm²309 A241 A4.28 V (17.83%)19.7 V7.06 V (29.42%)4280.0 WDrop High
185 mm²353 A275 A3.47 V (14.46%)20.5 V5.72 V (23.85%)3470.3 WDrop High
240 mm²415 A324 A2.67 V (11.15%)21.3 V4.41 V (18.39%)2675.0 WDrop High
300 mm²477 A372 A2.14 V (8.92%)21.9 V3.53 V (14.71%)2140.0 WDrop High
400 mm²570 A445 A1.6 V (6.69%)22.4 V2.65 V (11.03%)1605.0 WDrop High

FAQ — 1000 Amp Cable Size at 15 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 1000A at 15 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 3× 400 mm² copper cable for 1000A over 15m at 24V (voltage drop: 0.53V or 2.23%).

What is the power capacity of 1000A at 24V?

At unity power factor, 1000A at 24V supports 24.0 kW with a standard 1000A circuit breaker.