⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

325 Amp Cable Size at 400 Meters (400V Three-Phase (IEC European Grid))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 325 A over 400 m (1312.3 ft).

Copper Cable (≤3% Drop)2× 400 mm²Drop: 6.03V (1.5%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 19.87V (4.97%)
Voltage at Load394.0 VLine Loss: 3390.6 W
Max Power & Breaker225.17 kW350A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 325A at 400m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A3212.38 V (803.09%)0.0 V5298.92 V (1324.73%)1808300.0 WDrop High
2.5 mm²24 A18 A1927.43 V (481.86%)0.0 V3179.35 V (794.84%)1084980.0 WDrop High
4 mm²32 A25 A1204.64 V (301.16%)0.0 V1987.1 V (496.77%)678112.5 WDrop High
6 mm²41 A32 A803.09 V (200.77%)0.0 V1324.73 V (331.18%)452075.0 WDrop High
10 mm²57 A44 A481.86 V (120.46%)0.0 V794.84 V (198.71%)271245.0 WDrop High
16 mm²76 A59 A301.16 V (75.29%)98.8 V496.77 V (124.19%)169528.1 WDrop High
25 mm²101 A78 A192.74 V (48.19%)207.3 V317.94 V (79.48%)108498.0 WDrop High
35 mm²125 A97 A137.67 V (34.42%)262.3 V227.1 V (56.77%)77498.6 WDrop High
50 mm²151 A118 A96.37 V (24.09%)303.6 V158.97 V (39.74%)54249.0 WDrop High
70 mm²192 A150 A68.84 V (17.21%)331.2 V113.55 V (28.39%)38749.3 WDrop High
95 mm²232 A181 A50.72 V (12.68%)349.3 V83.67 V (20.92%)28552.1 WDrop High
120 mm²269 A210 A40.15 V (10.04%)359.8 V66.24 V (16.56%)22603.7 WDrop High
150 mm²309 A241 A32.12 V (8.03%)367.9 V52.99 V (13.25%)18083.0 WDrop High
185 mm²353 A275 A26.05 V (6.51%)374.0 V42.96 V (10.74%)14661.9 WDrop High
240 mm²415 A324 A20.08 V (5.02%)379.9 V33.12 V (8.28%)11301.9 WDrop High
300 mm²477 A372 A16.06 V (4.02%)383.9 V26.49 V (6.62%)9041.5 W~ ≤5%
400 mm²570 A445 A12.05 V (3.01%)388.0 V19.87 V (4.97%)6781.1 W~ ≤5%

FAQ — 325 Amp Cable Size at 400 Meters (400V Three-Phase (IEC European Grid))

What mm² cable size is required for 325A at 400 meters (400V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 2× 400 mm² copper cable for 325A over 400m at 400V (voltage drop: 6.03V or 1.5%).

What is the power capacity of 325A at 400V?

At unity power factor, 325A at 400V supports 225.17 kW with a standard 350A circuit breaker.