⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

700 Amp Cable Size at 35 Meters (230V Single-Phase (IEC Europe / UK / AU))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 700 A over 35 m (114.8 ft).

Copper Cable (≤3% Drop)2× 400 mm²Drop: 1.31V (0.57%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 4.32V (1.88%)
Voltage at Load228.7 VLine Loss: 917.5 W
Max Power & Breaker161.0 kW700A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 700A at 35m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A699.07 V (303.94%)0.0 V1153.13 V (501.36%)489346.7 WDrop High
2.5 mm²24 A18 A419.44 V (182.37%)0.0 V691.88 V (300.82%)293608.0 WDrop High
4 mm²32 A25 A262.15 V (113.98%)0.0 V432.43 V (188.01%)183505.0 WDrop High
6 mm²41 A32 A174.77 V (75.99%)55.2 V288.28 V (125.34%)122336.7 WDrop High
10 mm²57 A44 A104.86 V (45.59%)125.1 V172.97 V (75.2%)73402.0 WDrop High
16 mm²76 A59 A65.54 V (28.49%)164.5 V108.11 V (47.0%)45876.2 WDrop High
25 mm²101 A78 A41.94 V (18.24%)188.1 V69.19 V (30.08%)29360.8 WDrop High
35 mm²125 A97 A29.96 V (13.03%)200.0 V49.42 V (21.49%)20972.0 WDrop High
50 mm²151 A118 A20.97 V (9.12%)209.0 V34.59 V (15.04%)14680.4 WDrop High
70 mm²192 A150 A14.98 V (6.51%)215.0 V24.71 V (10.74%)10486.0 WDrop High
95 mm²232 A181 A11.04 V (4.8%)219.0 V18.21 V (7.92%)7726.5 WDrop High
120 mm²269 A210 A8.74 V (3.8%)221.3 V14.41 V (6.27%)6116.8 WDrop High
150 mm²309 A241 A6.99 V (3.04%)223.0 V11.53 V (5.01%)4893.5 WDrop High
185 mm²353 A275 A5.67 V (2.46%)224.3 V9.35 V (4.07%)3967.7 WDrop High
240 mm²415 A324 A4.37 V (1.9%)225.6 V7.21 V (3.13%)3058.4 WDrop High
300 mm²477 A372 A3.5 V (1.52%)226.5 V5.77 V (2.51%)2446.7 WDrop High
400 mm²570 A445 A2.62 V (1.14%)227.4 V4.32 V (1.88%)1835.0 WDrop High

FAQ — 700 Amp Cable Size at 35 Meters (230V Single-Phase (IEC Europe / UK / AU))

What mm² cable size is required for 700A at 35 meters (230V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 2× 400 mm² copper cable for 700A over 35m at 230V (voltage drop: 1.31V or 0.57%).

What is the power capacity of 700A at 230V?

At unity power factor, 700A at 230V supports 161.0 kW with a standard 700A circuit breaker.