🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

30 Amp Wire Size at 60 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 30 A load over a 60 ft (18.3 m) one-way run.

Copper Wire (≤3% Drop)2/0 AWG67.43 mm² · Drop: 2.9%
Aluminum Wire (≤3% Drop)250 kcmilDrop: 0.31V (2.55%)
Voltage at Load End11.7 VLoss: 0.35 V (10.4 W)
Power & Breaker (125%)0.36 kW40A Breaker Recommended

All AWG & kcmil Wire Gauges for 30 Amps at 60 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A11.29 V (94.08%)0.7 V18.62 V (155.18%)338.7 WDrop/Amp High
12 AWG3.31 mm²20 A7.09 V (59.12%)4.9 V11.7 V (97.52%)212.8 WDrop/Amp High
10 AWG5.26 mm²30 A4.46 V (37.2%)7.5 V7.36 V (61.37%)133.9 WDrop/Amp High
8 AWG8.37 mm²50 A2.81 V (23.38%)9.2 V4.63 V (38.56%)84.2 WDrop/Amp High
6 AWG13.3 mm²65 A1.77 V (14.71%)10.2 V2.91 V (24.27%)53.0 WDrop/Amp High
4 AWG21.15 mm²85 A1.11 V (9.25%)10.9 V1.83 V (15.26%)33.3 WDrop/Amp High
3 AWG26.67 mm²100 A0.88 V (7.34%)11.1 V1.45 V (12.1%)26.4 WDrop/Amp High
2 AWG33.62 mm²115 A0.7 V (5.82%)11.3 V1.15 V (9.6%)21.0 WDrop/Amp High
1 AWG42.41 mm²130 A0.55 V (4.61%)11.4 V0.91 V (7.61%)16.6 W~ ≤5%
1/0 AWG53.49 mm²150 A0.44 V (3.66%)11.6 V0.72 V (6.03%)13.2 W~ ≤5%
2/0 AWG67.43 mm²175 A0.35 V (2.9%)11.7 V0.57 V (4.79%)10.4 W✓ PASS (≤3%)
3/0 AWG85.01 mm²200 A0.28 V (2.3%)11.7 V0.46 V (3.8%)8.3 W✓ PASS (≤3%)
4/0 AWG107.2 mm²230 A0.22 V (1.83%)11.8 V0.36 V (3.01%)6.6 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.19 V (1.54%)11.8 V0.31 V (2.55%)5.6 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.15 V (1.29%)11.8 V0.25 V (2.12%)4.6 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.13 V (1.1%)11.9 V0.22 V (1.82%)4.0 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.12 V (0.97%)11.9 V0.19 V (1.59%)3.5 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.09 V (0.77%)11.9 V0.15 V (1.27%)2.8 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.08 V (0.64%)11.9 V0.13 V (1.06%)2.3 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.06 V (0.51%)11.9 V0.1 V (0.85%)1.9 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.05 V (0.39%)12.0 V0.08 V (0.64%)1.4 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 30 amps at 60 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 30A load over 60 feet one-way at 12V (DC), you need 2/0 AWG copper wire. This produces a voltage drop of 0.35V (2.9%) and delivers 11.7V at the load.

What size aluminum wire is required for 30 amps at 60 feet?

Using aluminum conductors (75°C rating), you should use 250 kcmil to maintain voltage drop at 0.31V (2.55%).

What breaker size is needed for a 30A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (30A × 1.25 = 37.5A), which corresponds to a standard 40A circuit breaker.