350 Amp Wire Size at 800 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 350 A load over a 800 ft (243.8 m) one-way run.

Copper Wire (≤3% Drop)21× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.86%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 11.89V (99.09%)
Voltage at Load End11.7 VLoss: 0.34 V (120.1 W)
Power & Breaker (125%)4.2 kW450A Breaker Recommended

All AWG & kcmil Wire Gauges for 350 Amps at 800 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1756.12 V (14634.31%)0.0 V2896.77 V (24139.77%)614640.9 WDrop/Amp High
12 AWG3.31 mm²20 A1103.54 V (9196.18%)0.0 V1820.33 V (15169.4%)386239.6 WDrop/Amp High
10 AWG5.26 mm²30 A694.43 V (5786.95%)0.0 V1145.49 V (9545.76%)243051.9 WDrop/Amp High
8 AWG8.37 mm²50 A436.41 V (3636.72%)0.0 V719.87 V (5998.89%)152742.3 WDrop/Amp High
6 AWG13.3 mm²65 A274.64 V (2288.67%)0.0 V453.03 V (3775.24%)96124.3 WDrop/Amp High
4 AWG21.15 mm²85 A172.71 V (1439.21%)0.0 V284.88 V (2374.03%)60447.0 WDrop/Amp High
3 AWG26.67 mm²100 A136.96 V (1141.33%)0.0 V225.92 V (1882.67%)47936.0 WDrop/Amp High
2 AWG33.62 mm²115 A108.65 V (905.39%)0.0 V179.22 V (1493.48%)38026.6 WDrop/Amp High
1 AWG42.41 mm²130 A86.13 V (717.74%)0.0 V142.07 V (1183.94%)30145.1 WDrop/Amp High
1/0 AWG53.49 mm²150 A68.29 V (569.07%)0.0 V112.64 V (938.69%)23900.8 WDrop/Amp High
2/0 AWG67.43 mm²175 A54.17 V (451.42%)0.0 V89.36 V (744.63%)18959.7 WDrop/Amp High
3/0 AWG85.01 mm²200 A42.97 V (358.07%)0.0 V70.88 V (590.64%)15038.9 WDrop/Amp High
4/0 AWG107.2 mm²230 A34.07 V (283.95%)0.0 V56.21 V (468.38%)11925.9 WDrop/Amp High
250 kcmil126.7 mm²255 A28.83 V (240.25%)0.0 V47.56 V (396.3%)10090.4 WDrop/Amp High
300 kcmil152.0 mm²285 A24.03 V (200.26%)0.0 V39.64 V (330.33%)8410.9 WDrop/Amp High
350 kcmil177.3 mm²310 A20.6 V (171.68%)0.0 V33.98 V (283.2%)7210.7 WDrop/Amp High
400 kcmil202.7 mm²335 A18.02 V (150.17%)0.0 V29.73 V (247.71%)6307.1 WDrop/Amp High
500 kcmil253.4 mm²380 A14.41 V (120.12%)0.0 V23.78 V (198.15%)5045.2 WDrop/Amp High
600 kcmil304.0 mm²420 A12.02 V (100.13%)0.0 V19.82 V (165.17%)4205.4 WDrop/Amp High
750 kcmil380.0 mm²475 A9.61 V (80.1%)2.4 V15.86 V (132.13%)3364.4 WDrop/Amp High
1000 kcmil506.7 mm²545 A7.21 V (60.07%)4.8 V11.89 V (99.09%)2523.1 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 350 amps at 800 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 350A load over 800 feet one-way at 12V (DC), you need 21× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.34V (2.86%) and delivers 11.7V at the load.

What size aluminum wire is required for 350 amps at 800 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 11.89V (99.09%).

What breaker size is needed for a 350A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (350A × 1.25 = 437.5A), which corresponds to a standard 450A circuit breaker.