⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

60 Amp Wire Size at 80 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 60 A load over a 80 ft (24.4 m) one-way run.

Copper Wire (≤3% Drop)350 kcmil177.3 mm² · Drop: 2.94%
Aluminum Wire (≤3% Drop)600 kcmilDrop: 0.34V (2.83%)
Voltage at Load End11.6 VLoss: 0.35 V (21.2 W)
Power & Breaker (125%)0.72 kW80A Breaker Recommended

All AWG & kcmil Wire Gauges for 60 Amps at 80 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A30.1 V (250.87%)0.0 V49.66 V (413.82%)1806.3 WDrop/Amp High
12 AWG3.31 mm²20 A18.92 V (157.65%)0.0 V31.21 V (260.05%)1135.1 WDrop/Amp High
10 AWG5.26 mm²30 A11.9 V (99.2%)0.1 V19.64 V (163.64%)714.3 WDrop/Amp High
8 AWG8.37 mm²50 A7.48 V (62.34%)4.5 V12.34 V (102.84%)448.9 WDrop/Amp High
6 AWG13.3 mm²65 A4.71 V (39.23%)7.3 V7.77 V (64.72%)282.5 WDrop/Amp High
4 AWG21.15 mm²85 A2.96 V (24.67%)9.0 V4.88 V (40.7%)177.6 WDrop/Amp High
3 AWG26.67 mm²100 A2.35 V (19.57%)9.7 V3.87 V (32.27%)140.9 WDrop/Amp High
2 AWG33.62 mm²115 A1.86 V (15.52%)10.1 V3.07 V (25.6%)111.8 WDrop/Amp High
1 AWG42.41 mm²130 A1.48 V (12.3%)10.5 V2.44 V (20.3%)88.6 WDrop/Amp High
1/0 AWG53.49 mm²150 A1.17 V (9.76%)10.8 V1.93 V (16.09%)70.2 WDrop/Amp High
2/0 AWG67.43 mm²175 A0.93 V (7.74%)11.1 V1.53 V (12.77%)55.7 WDrop/Amp High
3/0 AWG85.01 mm²200 A0.74 V (6.14%)11.3 V1.22 V (10.13%)44.2 WDrop/Amp High
4/0 AWG107.2 mm²230 A0.58 V (4.87%)11.4 V0.96 V (8.03%)35.0 W~ ≤5%
250 kcmil126.7 mm²255 A0.49 V (4.12%)11.5 V0.82 V (6.79%)29.7 W~ ≤5%
300 kcmil152.0 mm²285 A0.41 V (3.43%)11.6 V0.68 V (5.66%)24.7 W~ ≤5%
350 kcmil177.3 mm²310 A0.35 V (2.94%)11.6 V0.58 V (4.85%)21.2 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.31 V (2.57%)11.7 V0.51 V (4.25%)18.5 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.25 V (2.06%)11.8 V0.41 V (3.4%)14.8 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.21 V (1.72%)11.8 V0.34 V (2.83%)12.4 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.16 V (1.37%)11.8 V0.27 V (2.27%)9.9 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.12 V (1.03%)11.9 V0.2 V (1.7%)7.4 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 60 amps at 80 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 60A load over 80 feet one-way at 12V (DC), you need 350 kcmil copper wire. This produces a voltage drop of 0.35V (2.94%) and delivers 11.6V at the load.

What size aluminum wire is required for 60 amps at 80 feet?

Using aluminum conductors (75°C rating), you should use 600 kcmil to maintain voltage drop at 0.34V (2.83%).

What breaker size is needed for a 60A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (60A × 1.25 = 75.0A), which corresponds to a standard 80A circuit breaker.