⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

750 Amp Wire Size at 450 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 750 A load over a 450 ft (137.2 m) one-way run.

Copper Wire (≤3% Drop)25× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.9%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 14.33V (119.44%)
Voltage at Load End11.7 VLoss: 0.35 V (260.7 W)
Power & Breaker (125%)9.0 kW1000A Breaker Recommended

All AWG & kcmil Wire Gauges for 750 Amps at 450 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A2116.75 V (17639.57%)0.0 V3491.65 V (29097.04%)1587561.1 WDrop/Amp High
12 AWG3.31 mm²20 A1330.16 V (11084.68%)0.0 V2194.15 V (18284.55%)997621.5 WDrop/Amp High
10 AWG5.26 mm²30 A837.04 V (6975.34%)0.0 V1380.73 V (11506.06%)627780.8 WDrop/Amp High
8 AWG8.37 mm²50 A526.03 V (4383.55%)0.0 V867.7 V (7230.81%)394519.4 WDrop/Amp High
6 AWG13.3 mm²65 A331.04 V (2758.67%)0.0 V546.06 V (4550.52%)248280.2 WDrop/Amp High
4 AWG21.15 mm²85 A208.17 V (1734.77%)0.0 V343.39 V (2861.55%)156128.9 WDrop/Amp High
3 AWG26.67 mm²100 A165.09 V (1375.71%)0.0 V272.31 V (2269.29%)123814.3 WDrop/Amp High
2 AWG33.62 mm²115 A130.96 V (1091.32%)0.0 V216.02 V (1800.17%)98219.1 WDrop/Amp High
1 AWG42.41 mm²130 A103.82 V (865.13%)0.0 V171.25 V (1427.07%)77862.0 WDrop/Amp High
1/0 AWG53.49 mm²150 A82.31 V (685.93%)0.0 V135.78 V (1131.46%)61733.5 WDrop/Amp High
2/0 AWG67.43 mm²175 A65.29 V (544.12%)0.0 V107.71 V (897.55%)48971.2 WDrop/Amp High
3/0 AWG85.01 mm²200 A51.79 V (431.6%)0.0 V85.43 V (711.94%)38844.0 WDrop/Amp High
4/0 AWG107.2 mm²230 A41.07 V (342.26%)0.0 V67.75 V (564.57%)30803.4 WDrop/Amp High
250 kcmil126.7 mm²255 A34.75 V (289.58%)0.0 V57.32 V (477.68%)26062.6 WDrop/Amp High
300 kcmil152.0 mm²285 A28.97 V (241.38%)0.0 V47.78 V (398.17%)21724.5 WDrop/Amp High
350 kcmil177.3 mm²310 A24.83 V (206.94%)0.0 V40.96 V (341.35%)18624.5 WDrop/Amp High
400 kcmil202.7 mm²335 A21.72 V (181.01%)0.0 V35.83 V (298.58%)16290.7 WDrop/Amp High
500 kcmil253.4 mm²380 A17.38 V (144.79%)0.0 V28.66 V (238.84%)13031.3 WDrop/Amp High
600 kcmil304.0 mm²420 A14.48 V (120.69%)0.0 V23.89 V (199.09%)10862.3 WDrop/Amp High
750 kcmil380.0 mm²475 A11.59 V (96.55%)0.4 V19.11 V (159.27%)8689.8 WDrop/Amp High
1000 kcmil506.7 mm²545 A8.69 V (72.41%)3.3 V14.33 V (119.44%)6516.9 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 750 amps at 450 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 750A load over 450 feet one-way at 12V (DC), you need 25× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.35V (2.9%) and delivers 11.7V at the load.

What size aluminum wire is required for 750 amps at 450 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 14.33V (119.44%).

What breaker size is needed for a 750A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (750A × 1.25 = 937.5A), which corresponds to a standard 1000A circuit breaker.