Kabelarea för 750 Ampere vid 80 Meter (230V)
Komplett dimensionering av kabelarea (mm²), spänningsfall och säkring enligt svensk elstandard (SS 436 40 00 / IEC 60364) för 750 A över 80 m vid 230V.
Copper Cable (≤3% Drop)2× 400 mm²Drop: 3.21V (1.4%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 10.59V (4.6%)
Voltage at Load226.8 VLine Loss: 2407.5 W
Max Power & Breaker172.5 kW800A MCB/MCCB
IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 750A at 80m
| Cross-Section (mm²) | Cu Ampacity | Al Ampacity | Cu Voltage Drop | Load Voltage | Al Voltage Drop | Power Loss | Status |
|---|---|---|---|---|---|---|---|
| 1.5 mm² | 16 A | 12 A | 1712.0 V (744.35%) | 0.0 V | 2824.0 V (1227.83%) | 1284000.0 W | Drop High |
| 2.5 mm² | 24 A | 18 A | 1027.2 V (446.61%) | 0.0 V | 1694.4 V (736.7%) | 770400.0 W | Drop High |
| 4 mm² | 32 A | 25 A | 642.0 V (279.13%) | 0.0 V | 1059.0 V (460.43%) | 481500.0 W | Drop High |
| 6 mm² | 41 A | 32 A | 428.0 V (186.09%) | 0.0 V | 706.0 V (306.96%) | 321000.0 W | Drop High |
| 10 mm² | 57 A | 44 A | 256.8 V (111.65%) | 0.0 V | 423.6 V (184.17%) | 192600.0 W | Drop High |
| 16 mm² | 76 A | 59 A | 160.5 V (69.78%) | 69.5 V | 264.75 V (115.11%) | 120375.0 W | Drop High |
| 25 mm² | 101 A | 78 A | 102.72 V (44.66%) | 127.3 V | 169.44 V (73.67%) | 77040.0 W | Drop High |
| 35 mm² | 125 A | 97 A | 73.37 V (31.9%) | 156.6 V | 121.03 V (52.62%) | 55028.6 W | Drop High |
| 50 mm² | 151 A | 118 A | 51.36 V (22.33%) | 178.6 V | 84.72 V (36.83%) | 38520.0 W | Drop High |
| 70 mm² | 192 A | 150 A | 36.69 V (15.95%) | 193.3 V | 60.51 V (26.31%) | 27514.3 W | Drop High |
| 95 mm² | 232 A | 181 A | 27.03 V (11.75%) | 203.0 V | 44.59 V (19.39%) | 20273.7 W | Drop High |
| 120 mm² | 269 A | 210 A | 21.4 V (9.3%) | 208.6 V | 35.3 V (15.35%) | 16050.0 W | Drop High |
| 150 mm² | 309 A | 241 A | 17.12 V (7.44%) | 212.9 V | 28.24 V (12.28%) | 12840.0 W | Drop High |
| 185 mm² | 353 A | 275 A | 13.88 V (6.04%) | 216.1 V | 22.9 V (9.96%) | 10410.8 W | Drop High |
| 240 mm² | 415 A | 324 A | 10.7 V (4.65%) | 219.3 V | 17.65 V (7.67%) | 8025.0 W | Drop High |
| 300 mm² | 477 A | 372 A | 8.56 V (3.72%) | 221.4 V | 14.12 V (6.14%) | 6420.0 W | Drop High |
| 400 mm² | 570 A | 445 A | 6.42 V (2.79%) | 223.6 V | 10.59 V (4.6%) | 4815.0 W | Drop High |
FAQ — Kabelarea för 750 Ampere vid 80 Meter (230V)
Vilken kabelarea krävs för 750A vid 80 meter (230V)?
För 750 Ampere över 80 meter vid 230V rekommenderas 2× 400 mm² kopparkabel för att hålla spänningsfallet under 3% (3.21V / 1.4%).
Hur stor effekt motsvarar 750A vid 230V?
Det motsvarar 172.5 kW med en rekommenderad säkring på 800A.
Related Lengths & Currents (230V)
750A · 5m (230V)750A · 10m (230V)750A · 15m (230V)750A · 20m (230V)750A · 25m (230V)750A · 30m (230V)750A · 35m (230V)750A · 40m (230V)750A · 45m (230V)750A · 50m (230V)750A · 60m (230V)750A · 70m (230V)10A · 80m (230V)16A · 80m (230V)20A · 80m (230V)25A · 80m (230V)32A · 80m (230V)40A · 80m (230V)50A · 80m (230V)63A · 80m (230V)80A · 80m (230V)100A · 80m (230V)125A · 80m (230V)160A · 80m (230V)200A · 80m (230V)