10 Amp Wire Size at 175 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 10 A load over a 175 ft (53.3 m) one-way run.

Copper Wire (≤3% Drop)2/0 AWG67.43 mm² · Drop: 2.82%
Aluminum Wire (≤3% Drop)4/0 AWGDrop: 0.35V (2.93%)
Voltage at Load End11.7 VLoss: 0.34 V (3.4 W)
Power & Breaker (125%)0.12 kW13A Breaker Recommended

All AWG & kcmil Wire Gauges for 10 Amps at 175 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A10.98 V (91.46%)1.0 V18.1 V (150.87%)109.8 WDrop/Amp High
12 AWG3.31 mm²20 A6.9 V (57.48%)5.1 V11.38 V (94.81%)69.0 WDrop/Amp High
10 AWG5.26 mm²30 A4.34 V (36.17%)7.7 V7.16 V (59.66%)43.4 WDrop/Amp High
8 AWG8.37 mm²50 A2.73 V (22.73%)9.3 V4.5 V (37.49%)27.3 WDrop/Amp High
6 AWG13.3 mm²65 A1.72 V (14.3%)10.3 V2.83 V (23.6%)17.2 WDrop/Amp High
4 AWG21.15 mm²85 A1.08 V (9.0%)10.9 V1.78 V (14.84%)10.8 WDrop/Amp High
3 AWG26.67 mm²100 A0.86 V (7.13%)11.1 V1.41 V (11.77%)8.6 WDrop/Amp High
2 AWG33.62 mm²115 A0.68 V (5.66%)11.3 V1.12 V (9.33%)6.8 WDrop/Amp High
1 AWG42.41 mm²130 A0.54 V (4.49%)11.5 V0.89 V (7.4%)5.4 W~ ≤5%
1/0 AWG53.49 mm²150 A0.43 V (3.56%)11.6 V0.7 V (5.87%)4.3 W~ ≤5%
2/0 AWG67.43 mm²175 A0.34 V (2.82%)11.7 V0.56 V (4.65%)3.4 W✓ PASS (≤3%)
3/0 AWG85.01 mm²200 A0.27 V (2.24%)11.7 V0.44 V (3.69%)2.7 W✓ PASS (≤3%)
4/0 AWG107.2 mm²230 A0.21 V (1.77%)11.8 V0.35 V (2.93%)2.1 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.18 V (1.5%)11.8 V0.3 V (2.48%)1.8 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.15 V (1.25%)11.8 V0.25 V (2.06%)1.5 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.13 V (1.07%)11.9 V0.21 V (1.77%)1.3 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.11 V (0.94%)11.9 V0.19 V (1.55%)1.1 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.09 V (0.75%)11.9 V0.15 V (1.24%)0.9 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.08 V (0.63%)11.9 V0.12 V (1.03%)0.8 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.06 V (0.5%)11.9 V0.1 V (0.83%)0.6 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.05 V (0.38%)12.0 V0.07 V (0.62%)0.5 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 10 amps at 175 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 10A load over 175 feet one-way at 12V (DC), you need 2/0 AWG copper wire. This produces a voltage drop of 0.34V (2.82%) and delivers 11.7V at the load.

What size aluminum wire is required for 10 amps at 175 feet?

Using aluminum conductors (75°C rating), you should use 4/0 AWG to maintain voltage drop at 0.35V (2.93%).

What breaker size is needed for a 10A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (10A × 1.25 = 12.5A), which corresponds to a standard 13A circuit breaker.