10 Amp Wire Size at 50 Feet (480V Three-Phase (US Heavy Industrial))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 10 A load over a 50 ft (15.2 m) one-way run.

Copper Wire (≤3% Drop)14 AWG2.08 mm² · Drop: 0.57%
Aluminum Wire (≤3% Drop)14 AWGDrop: 4.48V (0.93%)
Voltage at Load End477.3 VLoss: 2.72 V (47.0 W)
Power & Breaker (125%)8.31 kW13A Breaker Recommended

All AWG & kcmil Wire Gauges for 10 Amps at 50 Feet (480V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A2.72 V (0.57%)477.3 V4.48 V (0.93%)47.0 W✓ PASS (≤3%)
12 AWG3.31 mm²20 A1.71 V (0.36%)478.3 V2.82 V (0.59%)29.6 W✓ PASS (≤3%)
10 AWG5.26 mm²30 A1.07 V (0.22%)478.9 V1.77 V (0.37%)18.6 W✓ PASS (≤3%)
8 AWG8.37 mm²50 A0.67 V (0.14%)479.3 V1.11 V (0.23%)11.7 W✓ PASS (≤3%)
6 AWG13.3 mm²65 A0.42 V (0.09%)479.6 V0.7 V (0.15%)7.4 W✓ PASS (≤3%)
4 AWG21.15 mm²85 A0.27 V (0.06%)479.7 V0.44 V (0.09%)4.6 W✓ PASS (≤3%)
3 AWG26.67 mm²100 A0.21 V (0.04%)479.8 V0.35 V (0.07%)3.7 W✓ PASS (≤3%)
2 AWG33.62 mm²115 A0.17 V (0.04%)479.8 V0.28 V (0.06%)2.9 W✓ PASS (≤3%)
1 AWG42.41 mm²130 A0.13 V (0.03%)479.9 V0.22 V (0.05%)2.3 W✓ PASS (≤3%)
1/0 AWG53.49 mm²150 A0.11 V (0.02%)479.9 V0.17 V (0.04%)1.8 W✓ PASS (≤3%)
2/0 AWG67.43 mm²175 A0.08 V (0.02%)479.9 V0.14 V (0.03%)1.5 W✓ PASS (≤3%)
3/0 AWG85.01 mm²200 A0.07 V (0.01%)479.9 V0.11 V (0.02%)1.2 W✓ PASS (≤3%)
4/0 AWG107.2 mm²230 A0.05 V (0.01%)479.9 V0.09 V (0.02%)0.9 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.04 V (0.01%)480.0 V0.07 V (0.02%)0.8 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.04 V (0.01%)480.0 V0.06 V (0.01%)0.6 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.03 V (0.01%)480.0 V0.05 V (0.01%)0.6 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.03 V (0.01%)480.0 V0.05 V (0.01%)0.5 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.02 V (0.0%)480.0 V0.04 V (0.01%)0.4 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.02 V (0.0%)480.0 V0.03 V (0.01%)0.3 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.01 V (0.0%)480.0 V0.02 V (0.01%)0.3 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.01 V (0.0%)480.0 V0.02 V (0.0%)0.2 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 10 amps at 50 feet (480V)?

To stay within the NEC recommended 3% maximum voltage drop for a 10A load over 50 feet one-way at 480V (3-Phase), you need 14 AWG copper wire. This produces a voltage drop of 2.72V (0.57%) and delivers 477.3V at the load.

What size aluminum wire is required for 10 amps at 50 feet?

Using aluminum conductors (75°C rating), you should use 14 AWG to maintain voltage drop at 4.48V (0.93%).

What breaker size is needed for a 10A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (10A × 1.25 = 12.5A), which corresponds to a standard 13A circuit breaker.