🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

25 Amp Wire Size at 75 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 25 A load over a 75 ft (22.9 m) one-way run.

Copper Wire (≤3% Drop)3/0 AWG85.01 mm² · Drop: 2.4%
Aluminum Wire (≤3% Drop)250 kcmilDrop: 0.32V (2.65%)
Voltage at Load End11.7 VLoss: 0.29 V (7.2 W)
Power & Breaker (125%)0.3 kW32A Breaker Recommended

All AWG & kcmil Wire Gauges for 25 Amps at 75 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A11.76 V (98.0%)0.2 V19.4 V (161.65%)294.0 WDrop/Amp High
12 AWG3.31 mm²20 A7.39 V (61.58%)4.6 V12.19 V (101.58%)184.7 WDrop/Amp High
10 AWG5.26 mm²30 A4.65 V (38.75%)7.3 V7.67 V (63.92%)116.3 WDrop/Amp High
8 AWG8.37 mm²50 A2.92 V (24.35%)9.1 V4.82 V (40.17%)73.1 WDrop/Amp High
6 AWG13.3 mm²65 A1.84 V (15.33%)10.2 V3.03 V (25.28%)46.0 WDrop/Amp High
4 AWG21.15 mm²85 A1.16 V (9.64%)10.8 V1.91 V (15.9%)28.9 WDrop/Amp High
3 AWG26.67 mm²100 A0.92 V (7.64%)11.1 V1.51 V (12.61%)22.9 WDrop/Amp High
2 AWG33.62 mm²115 A0.73 V (6.06%)11.3 V1.2 V (10.0%)18.2 WDrop/Amp High
1 AWG42.41 mm²130 A0.58 V (4.81%)11.4 V0.95 V (7.93%)14.4 W~ ≤5%
1/0 AWG53.49 mm²150 A0.46 V (3.81%)11.5 V0.75 V (6.29%)11.4 W~ ≤5%
2/0 AWG67.43 mm²175 A0.36 V (3.02%)11.6 V0.6 V (4.99%)9.1 W~ ≤5%
3/0 AWG85.01 mm²200 A0.29 V (2.4%)11.7 V0.47 V (3.96%)7.2 W✓ PASS (≤3%)
4/0 AWG107.2 mm²230 A0.23 V (1.9%)11.8 V0.38 V (3.14%)5.7 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.19 V (1.61%)11.8 V0.32 V (2.65%)4.8 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.16 V (1.34%)11.8 V0.27 V (2.21%)4.0 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.14 V (1.15%)11.9 V0.23 V (1.9%)3.4 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.12 V (1.01%)11.9 V0.2 V (1.66%)3.0 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.1 V (0.8%)11.9 V0.16 V (1.33%)2.4 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.08 V (0.67%)11.9 V0.13 V (1.11%)2.0 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.06 V (0.54%)11.9 V0.11 V (0.88%)1.6 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.05 V (0.4%)12.0 V0.08 V (0.66%)1.2 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 25 amps at 75 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 25A load over 75 feet one-way at 12V (DC), you need 3/0 AWG copper wire. This produces a voltage drop of 0.29V (2.4%) and delivers 11.7V at the load.

What size aluminum wire is required for 25 amps at 75 feet?

Using aluminum conductors (75°C rating), you should use 250 kcmil to maintain voltage drop at 0.32V (2.65%).

What breaker size is needed for a 25A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (25A × 1.25 = 31.2A), which corresponds to a standard 32A circuit breaker.