400 Amp Wire Size at 120 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 400 A load over a 120 ft (36.6 m) one-way run.

Copper Wire (≤3% Drop)4× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.58%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 2.04V (16.99%)
Voltage at Load End11.7 VLoss: 0.31 V (123.6 W)
Power & Breaker (125%)4.8 kW500A Breaker Recommended

All AWG & kcmil Wire Gauges for 400 Amps at 120 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A301.05 V (2508.74%)0.0 V496.59 V (4138.25%)120419.4 WDrop/Amp High
12 AWG3.31 mm²20 A189.18 V (1576.49%)0.0 V312.06 V (2600.47%)75671.4 WDrop/Amp High
10 AWG5.26 mm²30 A119.05 V (992.05%)0.0 V196.37 V (1636.42%)47618.3 WDrop/Amp High
8 AWG8.37 mm²50 A74.81 V (623.44%)0.0 V123.41 V (1028.38%)29925.0 WDrop/Amp High
6 AWG13.3 mm²65 A47.08 V (392.34%)0.0 V77.66 V (647.18%)18832.5 WDrop/Amp High
4 AWG21.15 mm²85 A29.61 V (246.72%)0.0 V48.84 V (406.98%)11842.7 WDrop/Amp High
3 AWG26.67 mm²100 A23.48 V (195.66%)0.0 V38.73 V (322.74%)9391.5 WDrop/Amp High
2 AWG33.62 mm²115 A18.63 V (155.21%)0.0 V30.72 V (256.02%)7450.1 WDrop/Amp High
1 AWG42.41 mm²130 A14.76 V (123.04%)0.0 V24.36 V (202.96%)5906.0 WDrop/Amp High
1/0 AWG53.49 mm²150 A11.71 V (97.55%)0.3 V19.31 V (160.92%)4682.6 WDrop/Amp High
2/0 AWG67.43 mm²175 A9.29 V (77.39%)2.7 V15.32 V (127.65%)3714.6 WDrop/Amp High
3/0 AWG85.01 mm²200 A7.37 V (61.38%)4.6 V12.15 V (101.25%)2946.4 WDrop/Amp High
4/0 AWG107.2 mm²230 A5.84 V (48.68%)6.2 V9.64 V (80.29%)2336.5 WDrop/Amp High
250 kcmil126.7 mm²255 A4.94 V (41.19%)7.1 V8.15 V (67.94%)1976.9 WDrop/Amp High
300 kcmil152.0 mm²285 A4.12 V (34.33%)7.9 V6.8 V (56.63%)1647.8 WDrop/Amp High
350 kcmil177.3 mm²310 A3.53 V (29.43%)8.5 V5.83 V (48.55%)1412.7 WDrop/Amp High
400 kcmil202.7 mm²335 A3.09 V (25.74%)8.9 V5.1 V (42.46%)1235.7 WDrop/Amp High
500 kcmil253.4 mm²380 A2.47 V (20.59%)9.5 V4.08 V (33.97%)988.4 WDrop/Amp High
600 kcmil304.0 mm²420 A2.06 V (17.17%)9.9 V3.4 V (28.31%)823.9 WDrop/Amp High
750 kcmil380.0 mm²475 A1.65 V (13.73%)10.4 V2.72 V (22.65%)659.1 WDrop/Amp High
1000 kcmil506.7 mm²545 A1.24 V (10.3%)10.8 V2.04 V (16.99%)494.3 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 400 amps at 120 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 400A load over 120 feet one-way at 12V (DC), you need 4× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.31V (2.58%) and delivers 11.7V at the load.

What size aluminum wire is required for 400 amps at 120 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 2.04V (16.99%).

What breaker size is needed for a 400A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (400A × 1.25 = 500.0A), which corresponds to a standard 500A circuit breaker.