400 Amp Wire Size at 500 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 400 A load over a 500 ft (152.4 m) one-way run.

Copper Wire (≤3% Drop)15× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.86%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 8.49V (70.78%)
Voltage at Load End11.7 VLoss: 0.34 V (137.3 W)
Power & Breaker (125%)4.8 kW500A Breaker Recommended

All AWG & kcmil Wire Gauges for 400 Amps at 500 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1254.37 V (10453.08%)0.0 V2069.12 V (17242.69%)501747.7 WDrop/Amp High
12 AWG3.31 mm²20 A788.24 V (6568.7%)0.0 V1300.23 V (10835.29%)315297.6 WDrop/Amp High
10 AWG5.26 mm²30 A496.02 V (4133.54%)0.0 V818.21 V (6818.4%)198409.7 WDrop/Amp High
8 AWG8.37 mm²50 A311.72 V (2597.66%)0.0 V514.19 V (4284.92%)124687.6 WDrop/Amp High
6 AWG13.3 mm²65 A196.17 V (1634.77%)0.0 V323.59 V (2696.6%)78468.8 WDrop/Amp High
4 AWG21.15 mm²85 A123.36 V (1028.01%)0.0 V203.49 V (1695.74%)49344.5 WDrop/Amp High
3 AWG26.67 mm²100 A97.83 V (815.24%)0.0 V161.37 V (1344.76%)39131.4 WDrop/Amp High
2 AWG33.62 mm²115 A77.61 V (646.71%)0.0 V128.01 V (1066.77%)31042.1 WDrop/Amp High
1 AWG42.41 mm²130 A61.52 V (512.67%)0.0 V101.48 V (845.67%)24608.2 WDrop/Amp High
1/0 AWG53.49 mm²150 A48.78 V (406.48%)0.0 V80.46 V (670.5%)19510.8 WDrop/Amp High
2/0 AWG67.43 mm²175 A38.69 V (322.44%)0.0 V63.83 V (531.88%)15477.3 WDrop/Amp High
3/0 AWG85.01 mm²200 A30.69 V (255.76%)0.0 V50.63 V (421.89%)12276.6 WDrop/Amp High
4/0 AWG107.2 mm²230 A24.34 V (202.82%)0.0 V40.15 V (334.56%)9735.4 WDrop/Amp High
250 kcmil126.7 mm²255 A20.59 V (171.61%)0.0 V33.97 V (283.07%)8237.1 WDrop/Amp High
300 kcmil152.0 mm²285 A17.17 V (143.04%)0.0 V28.31 V (235.95%)6866.0 WDrop/Amp High
350 kcmil177.3 mm²310 A14.72 V (122.63%)0.0 V24.27 V (202.28%)5886.3 WDrop/Amp High
400 kcmil202.7 mm²335 A12.87 V (107.26%)0.0 V21.23 V (176.94%)5148.7 WDrop/Amp High
500 kcmil253.4 mm²380 A10.3 V (85.8%)1.7 V16.98 V (141.53%)4118.5 WDrop/Amp High
600 kcmil304.0 mm²420 A8.58 V (71.52%)3.4 V14.16 V (117.98%)3433.0 WDrop/Amp High
750 kcmil380.0 mm²475 A6.87 V (57.22%)5.1 V11.33 V (94.38%)2746.4 WDrop/Amp High
1000 kcmil506.7 mm²545 A5.15 V (42.91%)6.9 V8.49 V (70.78%)2059.7 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 400 amps at 500 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 400A load over 500 feet one-way at 12V (DC), you need 15× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.34V (2.86%) and delivers 11.7V at the load.

What size aluminum wire is required for 400 amps at 500 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 8.49V (70.78%).

What breaker size is needed for a 400A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (400A × 1.25 = 500.0A), which corresponds to a standard 500A circuit breaker.