🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

550 Amp Wire Size at 500 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 550 A load over a 500 ft (152.4 m) one-way run.

Copper Wire (≤3% Drop)20× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.95%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 11.68V (97.32%)
Voltage at Load End11.7 VLoss: 0.35 V (194.7 W)
Power & Breaker (125%)6.6 kW700A Breaker Recommended

All AWG & kcmil Wire Gauges for 550 Amps at 500 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1724.76 V (14372.98%)0.0 V2845.04 V (23708.7%)948616.7 WDrop/Amp High
12 AWG3.31 mm²20 A1083.84 V (9031.96%)0.0 V1787.82 V (14898.52%)596109.6 WDrop/Amp High
10 AWG5.26 mm²30 A682.03 V (5683.61%)0.0 V1125.04 V (9375.3%)375118.4 WDrop/Amp High
8 AWG8.37 mm²50 A428.61 V (3571.78%)0.0 V707.01 V (5891.77%)235737.5 WDrop/Amp High
6 AWG13.3 mm²65 A269.74 V (2247.8%)0.0 V444.94 V (3707.83%)148355.1 WDrop/Amp High
4 AWG21.15 mm²85 A169.62 V (1413.51%)0.0 V279.8 V (2331.64%)93291.9 WDrop/Amp High
3 AWG26.67 mm²100 A134.51 V (1120.95%)0.0 V221.89 V (1849.05%)73982.9 WDrop/Amp High
2 AWG33.62 mm²115 A106.71 V (889.23%)0.0 V176.02 V (1466.81%)58689.0 WDrop/Amp High
1 AWG42.41 mm²130 A84.59 V (704.92%)0.0 V139.54 V (1162.79%)46524.9 WDrop/Amp High
1/0 AWG53.49 mm²150 A67.07 V (558.9%)0.0 V110.63 V (921.93%)36887.7 WDrop/Amp High
2/0 AWG67.43 mm²175 A53.2 V (443.36%)0.0 V87.76 V (731.34%)29261.8 WDrop/Amp High
3/0 AWG85.01 mm²200 A42.2 V (351.67%)0.0 V69.61 V (580.1%)23210.5 WDrop/Amp High
4/0 AWG107.2 mm²230 A33.47 V (278.88%)0.0 V55.2 V (460.02%)18406.0 WDrop/Amp High
250 kcmil126.7 mm²255 A28.31 V (235.96%)0.0 V46.71 V (389.22%)15573.2 WDrop/Amp High
300 kcmil152.0 mm²285 A23.6 V (196.68%)0.0 V38.93 V (324.43%)12981.1 WDrop/Amp High
350 kcmil177.3 mm²310 A20.23 V (168.62%)0.0 V33.38 V (278.14%)11128.7 WDrop/Amp High
400 kcmil202.7 mm²335 A17.7 V (147.49%)0.0 V29.19 V (243.29%)9734.2 WDrop/Amp High
500 kcmil253.4 mm²380 A14.16 V (117.98%)0.0 V23.35 V (194.61%)7786.6 WDrop/Amp High
600 kcmil304.0 mm²420 A11.8 V (98.34%)0.2 V19.47 V (162.22%)6490.5 WDrop/Amp High
750 kcmil380.0 mm²475 A9.44 V (78.67%)2.6 V15.57 V (129.77%)5192.4 WDrop/Amp High
1000 kcmil506.7 mm²545 A7.08 V (59.0%)4.9 V11.68 V (97.32%)3894.1 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 550 amps at 500 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 550A load over 500 feet one-way at 12V (DC), you need 20× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.35V (2.95%) and delivers 11.7V at the load.

What size aluminum wire is required for 550 amps at 500 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 11.68V (97.32%).

What breaker size is needed for a 550A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (550A × 1.25 = 687.5A), which corresponds to a standard 700A circuit breaker.