⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

750 Amp Wire Size at 750 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 750 A load over a 750 ft (228.6 m) one-way run.

Copper Wire (≤3% Drop)41× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.94%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 23.89V (199.07%)
Voltage at Load End11.7 VLoss: 0.35 V (264.9 W)
Power & Breaker (125%)9.0 kW1000A Breaker Recommended

All AWG & kcmil Wire Gauges for 750 Amps at 750 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A3527.91 V (29399.28%)0.0 V5819.41 V (48495.07%)2645935.1 WDrop/Amp High
12 AWG3.31 mm²20 A2216.94 V (18474.47%)0.0 V3656.91 V (30474.24%)1662702.4 WDrop/Amp High
10 AWG5.26 mm²30 A1395.07 V (11625.57%)0.0 V2301.21 V (19176.76%)1046301.3 WDrop/Amp High
8 AWG8.37 mm²50 A876.71 V (7305.91%)0.0 V1446.16 V (12051.34%)657532.3 WDrop/Amp High
6 AWG13.3 mm²65 A551.73 V (4597.78%)0.0 V910.1 V (7584.19%)413800.4 WDrop/Amp High
4 AWG21.15 mm²85 A346.95 V (2891.28%)0.0 V572.31 V (4769.26%)260214.9 WDrop/Amp High
3 AWG26.67 mm²100 A275.14 V (2292.86%)0.0 V453.86 V (3782.14%)206357.1 WDrop/Amp High
2 AWG33.62 mm²115 A218.26 V (1818.87%)0.0 V360.03 V (3000.29%)163698.5 WDrop/Amp High
1 AWG42.41 mm²130 A173.03 V (1441.89%)0.0 V285.41 V (2378.44%)129770.0 WDrop/Amp High
1/0 AWG53.49 mm²150 A137.19 V (1143.21%)0.0 V226.29 V (1885.77%)102889.2 WDrop/Amp High
2/0 AWG67.43 mm²175 A108.82 V (906.87%)0.0 V179.51 V (1495.92%)81618.6 WDrop/Amp High
3/0 AWG85.01 mm²200 A86.32 V (719.33%)0.0 V142.39 V (1186.56%)64740.0 WDrop/Amp High
4/0 AWG107.2 mm²230 A68.45 V (570.43%)0.0 V112.91 V (940.95%)51339.0 WDrop/Amp High
250 kcmil126.7 mm²255 A57.92 V (482.64%)0.0 V95.54 V (796.13%)43437.6 WDrop/Amp High
300 kcmil152.0 mm²285 A48.28 V (402.31%)0.0 V79.63 V (663.62%)36207.5 WDrop/Amp High
350 kcmil177.3 mm²310 A41.39 V (344.9%)0.0 V68.27 V (568.92%)31040.9 WDrop/Amp High
400 kcmil202.7 mm²335 A36.2 V (301.68%)0.0 V59.72 V (497.63%)27151.2 WDrop/Amp High
500 kcmil253.4 mm²380 A28.96 V (241.32%)0.0 V47.77 V (398.07%)21718.8 WDrop/Amp High
600 kcmil304.0 mm²420 A24.14 V (201.15%)0.0 V39.82 V (331.81%)18103.8 WDrop/Amp High
750 kcmil380.0 mm²475 A19.31 V (160.92%)0.0 V31.85 V (265.45%)14483.0 WDrop/Amp High
1000 kcmil506.7 mm²545 A14.48 V (120.68%)0.0 V23.89 V (199.07%)10861.5 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 750 amps at 750 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 750A load over 750 feet one-way at 12V (DC), you need 41× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.35V (2.94%) and delivers 11.7V at the load.

What size aluminum wire is required for 750 amps at 750 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 23.89V (199.07%).

What breaker size is needed for a 750A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (750A × 1.25 = 937.5A), which corresponds to a standard 1000A circuit breaker.