50 Amp Wire Size at 750 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 50 A load over a 750 ft (228.6 m) one-way run.

Copper Wire (≤3% Drop)3× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.68%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 1.59V (13.27%)
Voltage at Load End11.7 VLoss: 0.32 V (16.1 W)
Power & Breaker (125%)0.6 kW63A Breaker Recommended

All AWG & kcmil Wire Gauges for 50 Amps at 750 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A235.19 V (1959.95%)0.0 V387.96 V (3233.0%)11759.7 WDrop/Amp High
12 AWG3.31 mm²20 A147.8 V (1231.63%)0.0 V243.79 V (2031.62%)7389.8 WDrop/Amp High
10 AWG5.26 mm²30 A93.0 V (775.04%)0.0 V153.41 V (1278.45%)4650.2 WDrop/Amp High
8 AWG8.37 mm²50 A58.45 V (487.06%)0.0 V96.41 V (803.42%)2922.4 WDrop/Amp High
6 AWG13.3 mm²65 A36.78 V (306.52%)0.0 V60.67 V (505.61%)1839.1 WDrop/Amp High
4 AWG21.15 mm²85 A23.13 V (192.75%)0.0 V38.15 V (317.95%)1156.5 WDrop/Amp High
3 AWG26.67 mm²100 A18.34 V (152.86%)0.0 V30.26 V (252.14%)917.1 WDrop/Amp High
2 AWG33.62 mm²115 A14.55 V (121.26%)0.0 V24.0 V (200.02%)727.5 WDrop/Amp High
1 AWG42.41 mm²130 A11.54 V (96.13%)0.5 V19.03 V (158.56%)576.8 WDrop/Amp High
1/0 AWG53.49 mm²150 A9.15 V (76.21%)2.9 V15.09 V (125.72%)457.3 WDrop/Amp High
2/0 AWG67.43 mm²175 A7.25 V (60.46%)4.7 V11.97 V (99.73%)362.7 WDrop/Amp High
3/0 AWG85.01 mm²200 A5.75 V (47.96%)6.2 V9.49 V (79.1%)287.7 WDrop/Amp High
4/0 AWG107.2 mm²230 A4.56 V (38.03%)7.4 V7.53 V (62.73%)228.2 WDrop/Amp High
250 kcmil126.7 mm²255 A3.86 V (32.18%)8.1 V6.37 V (53.08%)193.1 WDrop/Amp High
300 kcmil152.0 mm²285 A3.22 V (26.82%)8.8 V5.31 V (44.24%)160.9 WDrop/Amp High
350 kcmil177.3 mm²310 A2.76 V (22.99%)9.2 V4.55 V (37.93%)138.0 WDrop/Amp High
400 kcmil202.7 mm²335 A2.41 V (20.11%)9.6 V3.98 V (33.18%)120.7 WDrop/Amp High
500 kcmil253.4 mm²380 A1.93 V (16.09%)10.1 V3.18 V (26.54%)96.5 WDrop/Amp High
600 kcmil304.0 mm²420 A1.61 V (13.41%)10.4 V2.65 V (22.12%)80.5 WDrop/Amp High
750 kcmil380.0 mm²475 A1.29 V (10.73%)10.7 V2.12 V (17.7%)64.4 WDrop/Amp High
1000 kcmil506.7 mm²545 A0.97 V (8.05%)11.0 V1.59 V (13.27%)48.3 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 50 amps at 750 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 50A load over 750 feet one-way at 12V (DC), you need 3× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.32V (2.68%) and delivers 11.7V at the load.

What size aluminum wire is required for 50 amps at 750 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 1.59V (13.27%).

What breaker size is needed for a 50A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (50A × 1.25 = 62.5A), which corresponds to a standard 63A circuit breaker.