⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

150 Amp Cable Size at 250 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 150 A over 250 m (820.2 ft).

Copper Cable (≤3% Drop)6× 400 mm²Drop: 0.67V (2.79%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 6.62V (27.58%)
Voltage at Load23.3 VLine Loss: 100.3 W
Max Power & Breaker3.6 kW150A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 150A at 250m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A1070.0 V (4458.33%)0.0 V1765.0 V (7354.17%)160500.0 WDrop High
2.5 mm²24 A18 A642.0 V (2675.0%)0.0 V1059.0 V (4412.5%)96300.0 WDrop High
4 mm²32 A25 A401.25 V (1671.88%)0.0 V661.88 V (2757.81%)60187.5 WDrop High
6 mm²41 A32 A267.5 V (1114.58%)0.0 V441.25 V (1838.54%)40125.0 WDrop High
10 mm²57 A44 A160.5 V (668.75%)0.0 V264.75 V (1103.12%)24075.0 WDrop High
16 mm²76 A59 A100.31 V (417.97%)0.0 V165.47 V (689.45%)15046.9 WDrop High
25 mm²101 A78 A64.2 V (267.5%)0.0 V105.9 V (441.25%)9630.0 WDrop High
35 mm²125 A97 A45.86 V (191.07%)0.0 V75.64 V (315.18%)6878.6 WDrop High
50 mm²151 A118 A32.1 V (133.75%)0.0 V52.95 V (220.62%)4815.0 WDrop High
70 mm²192 A150 A22.93 V (95.54%)1.1 V37.82 V (157.59%)3439.3 WDrop High
95 mm²232 A181 A16.89 V (70.39%)7.1 V27.87 V (116.12%)2534.2 WDrop High
120 mm²269 A210 A13.37 V (55.73%)10.6 V22.06 V (91.93%)2006.2 WDrop High
150 mm²309 A241 A10.7 V (44.58%)13.3 V17.65 V (73.54%)1605.0 WDrop High
185 mm²353 A275 A8.68 V (36.15%)15.3 V14.31 V (59.63%)1301.4 WDrop High
240 mm²415 A324 A6.69 V (27.86%)17.3 V11.03 V (45.96%)1003.1 WDrop High
300 mm²477 A372 A5.35 V (22.29%)18.6 V8.82 V (36.77%)802.5 WDrop High
400 mm²570 A445 A4.01 V (16.72%)20.0 V6.62 V (27.58%)601.9 WDrop High

FAQ — 150 Amp Cable Size at 250 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 150A at 250 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 6× 400 mm² copper cable for 150A over 250m at 24V (voltage drop: 0.67V or 2.79%).

What is the power capacity of 150A at 24V?

At unity power factor, 150A at 24V supports 3.6 kW with a standard 150A circuit breaker.