⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

375 Amp Cable Size at 600 Meters (690V Three-Phase (Wind / Heavy Industrial))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 375 A over 600 m (1968.5 ft).

Copper Cable (≤3% Drop)2× 400 mm²Drop: 10.43V (1.51%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 34.39V (4.98%)
Voltage at Load679.6 VLine Loss: 6771.1 W
Max Power & Breaker448.17 kW400A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 375A at 600m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A5559.88 V (805.78%)0.0 V9171.21 V (1329.16%)3611250.0 WDrop High
2.5 mm²24 A18 A3335.93 V (483.47%)0.0 V5502.73 V (797.5%)2166750.0 WDrop High
4 mm²32 A25 A2084.96 V (302.17%)0.0 V3439.2 V (498.44%)1354218.8 WDrop High
6 mm²41 A32 A1389.97 V (201.45%)0.0 V2292.8 V (332.29%)902812.5 WDrop High
10 mm²57 A44 A833.98 V (120.87%)0.0 V1375.68 V (199.37%)541687.5 WDrop High
16 mm²76 A59 A521.24 V (75.54%)168.8 V859.8 V (124.61%)338554.7 WDrop High
25 mm²101 A78 A333.59 V (48.35%)356.4 V550.27 V (79.75%)216675.0 WDrop High
35 mm²125 A97 A238.28 V (34.53%)451.7 V393.05 V (56.96%)154767.9 WDrop High
50 mm²151 A118 A166.8 V (24.17%)523.2 V275.14 V (39.87%)108337.5 WDrop High
70 mm²192 A150 A119.14 V (17.27%)570.9 V196.53 V (28.48%)77383.9 WDrop High
95 mm²232 A181 A87.79 V (12.72%)602.2 V144.81 V (20.99%)57019.7 WDrop High
120 mm²269 A210 A69.5 V (10.07%)620.5 V114.64 V (16.61%)45140.6 WDrop High
150 mm²309 A241 A55.6 V (8.06%)634.4 V91.71 V (13.29%)36112.5 WDrop High
185 mm²353 A275 A45.08 V (6.53%)644.9 V74.36 V (10.78%)29280.4 WDrop High
240 mm²415 A324 A34.75 V (5.04%)655.3 V57.32 V (8.31%)22570.3 WDrop High
300 mm²477 A372 A27.8 V (4.03%)662.2 V45.86 V (6.65%)18056.2 W~ ≤5%
400 mm²570 A445 A20.85 V (3.02%)669.2 V34.39 V (4.98%)13542.2 W~ ≤5%

FAQ — 375 Amp Cable Size at 600 Meters (690V Three-Phase (Wind / Heavy Industrial))

What mm² cable size is required for 375A at 600 meters (690V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 2× 400 mm² copper cable for 375A over 600m at 690V (voltage drop: 10.43V or 1.51%).

What is the power capacity of 375A at 690V?

At unity power factor, 375A at 690V supports 448.17 kW with a standard 400A circuit breaker.