550 Amp Cable Size at 250 Meters (690V Three-Phase (Wind / Heavy Industrial))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 550 A over 250 m (820.2 ft).

Copper Cable (≤3% Drop)400 mm²Drop: 12.74V (1.85%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 21.02V (3.05%)
Voltage at Load677.3 VLine Loss: 12137.8 W
Max Power & Breaker657.31 kW600A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 550A at 250m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A3397.71 V (492.42%)0.0 V5604.63 V (812.26%)3236750.0 WDrop High
2.5 mm²24 A18 A2038.62 V (295.45%)0.0 V3362.78 V (487.36%)1942050.0 WDrop High
4 mm²32 A25 A1274.14 V (184.66%)0.0 V2101.74 V (304.6%)1213781.2 WDrop High
6 mm²41 A32 A849.43 V (123.11%)0.0 V1401.16 V (203.07%)809187.5 WDrop High
10 mm²57 A44 A509.66 V (73.86%)180.3 V840.69 V (121.84%)485512.5 WDrop High
16 mm²76 A59 A318.53 V (46.16%)371.5 V525.43 V (76.15%)303445.3 WDrop High
25 mm²101 A78 A203.86 V (29.55%)486.1 V336.28 V (48.74%)194205.0 WDrop High
35 mm²125 A97 A145.62 V (21.1%)544.4 V240.2 V (34.81%)138717.9 WDrop High
50 mm²151 A118 A101.93 V (14.77%)588.1 V168.14 V (24.37%)97102.5 WDrop High
70 mm²192 A150 A72.81 V (10.55%)617.2 V120.1 V (17.41%)69358.9 WDrop High
95 mm²232 A181 A53.65 V (7.78%)636.4 V88.49 V (12.83%)51106.6 WDrop High
120 mm²269 A210 A42.47 V (6.16%)647.5 V70.06 V (10.15%)40459.4 WDrop High
150 mm²309 A241 A33.98 V (4.92%)656.0 V56.05 V (8.12%)32367.5 WDrop High
185 mm²353 A275 A27.55 V (3.99%)662.5 V45.44 V (6.59%)26243.9 WDrop High
240 mm²415 A324 A21.24 V (3.08%)668.8 V35.03 V (5.08%)20229.7 WDrop High
300 mm²477 A372 A16.99 V (2.46%)673.0 V28.02 V (4.06%)16183.8 WDrop High
400 mm²570 A445 A12.74 V (1.85%)677.3 V21.02 V (3.05%)12137.8 W✓ OK (≤3%)

FAQ — 550 Amp Cable Size at 250 Meters (690V Three-Phase (Wind / Heavy Industrial))

What mm² cable size is required for 550A at 250 meters (690V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 400 mm² copper cable for 550A over 250m at 690V (voltage drop: 12.74V or 1.85%).

What is the power capacity of 550A at 690V?

At unity power factor, 550A at 690V supports 657.31 kW with a standard 600A circuit breaker.