Kabelarea för 450 Ampere vid 350 Meter (230V)
Komplett dimensionering av kabelarea (mm²), spänningsfall och säkring enligt svensk elstandard (SS 436 40 00 / IEC 60364) för 450 A över 350 m vid 230V.
Copper Cable (≤3% Drop)3× 400 mm²Drop: 5.62V (2.44%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 27.8V (12.09%)
Voltage at Load224.4 VLine Loss: 2527.9 W
Max Power & Breaker103.5 kW450A MCB/MCCB
IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 450A at 350m
| Cross-Section (mm²) | Cu Ampacity | Al Ampacity | Cu Voltage Drop | Load Voltage | Al Voltage Drop | Power Loss | Status |
|---|---|---|---|---|---|---|---|
| 1.5 mm² | 16 A | 12 A | 4494.0 V (1953.91%) | 0.0 V | 7413.0 V (3223.04%) | 2022300.0 W | Drop High |
| 2.5 mm² | 24 A | 18 A | 2696.4 V (1172.35%) | 0.0 V | 4447.8 V (1933.83%) | 1213380.0 W | Drop High |
| 4 mm² | 32 A | 25 A | 1685.25 V (732.72%) | 0.0 V | 2779.87 V (1208.64%) | 758362.5 W | Drop High |
| 6 mm² | 41 A | 32 A | 1123.5 V (488.48%) | 0.0 V | 1853.25 V (805.76%) | 505575.0 W | Drop High |
| 10 mm² | 57 A | 44 A | 674.1 V (293.09%) | 0.0 V | 1111.95 V (483.46%) | 303345.0 W | Drop High |
| 16 mm² | 76 A | 59 A | 421.31 V (183.18%) | 0.0 V | 694.97 V (302.16%) | 189590.6 W | Drop High |
| 25 mm² | 101 A | 78 A | 269.64 V (117.23%) | 0.0 V | 444.78 V (193.38%) | 121338.0 W | Drop High |
| 35 mm² | 125 A | 97 A | 192.6 V (83.74%) | 37.4 V | 317.7 V (138.13%) | 86670.0 W | Drop High |
| 50 mm² | 151 A | 118 A | 134.82 V (58.62%) | 95.2 V | 222.39 V (96.69%) | 60669.0 W | Drop High |
| 70 mm² | 192 A | 150 A | 96.3 V (41.87%) | 133.7 V | 158.85 V (69.07%) | 43335.0 W | Drop High |
| 95 mm² | 232 A | 181 A | 70.96 V (30.85%) | 159.0 V | 117.05 V (50.89%) | 31931.1 W | Drop High |
| 120 mm² | 269 A | 210 A | 56.17 V (24.42%) | 173.8 V | 92.66 V (40.29%) | 25278.7 W | Drop High |
| 150 mm² | 309 A | 241 A | 44.94 V (19.54%) | 185.1 V | 74.13 V (32.23%) | 20223.0 W | Drop High |
| 185 mm² | 353 A | 275 A | 36.44 V (15.84%) | 193.6 V | 60.11 V (26.13%) | 16397.0 W | Drop High |
| 240 mm² | 415 A | 324 A | 28.09 V (12.21%) | 201.9 V | 46.33 V (20.14%) | 12639.4 W | Drop High |
| 300 mm² | 477 A | 372 A | 22.47 V (9.77%) | 207.5 V | 37.06 V (16.12%) | 10111.5 W | Drop High |
| 400 mm² | 570 A | 445 A | 16.85 V (7.33%) | 213.1 V | 27.8 V (12.09%) | 7583.6 W | Drop High |
FAQ — Kabelarea för 450 Ampere vid 350 Meter (230V)
Vilken kabelarea krävs för 450A vid 350 meter (230V)?
För 450 Ampere över 350 meter vid 230V rekommenderas 3× 400 mm² kopparkabel för att hålla spänningsfallet under 3% (5.62V / 2.44%).
Hur stor effekt motsvarar 450A vid 230V?
Det motsvarar 103.5 kW med en rekommenderad säkring på 450A.
Related Lengths & Currents (230V)
450A · 5m (230V)450A · 10m (230V)450A · 15m (230V)450A · 20m (230V)450A · 25m (230V)450A · 30m (230V)450A · 35m (230V)450A · 40m (230V)450A · 45m (230V)450A · 50m (230V)450A · 60m (230V)450A · 70m (230V)10A · 350m (230V)16A · 350m (230V)20A · 350m (230V)25A · 350m (230V)32A · 350m (230V)40A · 350m (230V)50A · 350m (230V)63A · 350m (230V)80A · 350m (230V)100A · 350m (230V)125A · 350m (230V)160A · 350m (230V)200A · 350m (230V)