🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

250 Amp Wire Size at 750 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 250 A load over a 750 ft (228.6 m) one-way run.

Copper Wire (≤3% Drop)14× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.87%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 7.96V (66.36%)
Voltage at Load End11.7 VLoss: 0.35 V (86.2 W)
Power & Breaker (125%)3.0 kW350A Breaker Recommended

All AWG & kcmil Wire Gauges for 250 Amps at 750 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1175.97 V (9799.76%)0.0 V1939.8 V (16165.02%)293992.8 WDrop/Amp High
12 AWG3.31 mm²20 A738.98 V (6158.16%)0.0 V1218.97 V (10158.08%)184744.7 WDrop/Amp High
10 AWG5.26 mm²30 A465.02 V (3875.19%)0.0 V767.07 V (6392.25%)116255.7 WDrop/Amp High
8 AWG8.37 mm²50 A292.24 V (2435.3%)0.0 V482.05 V (4017.11%)73059.1 WDrop/Amp High
6 AWG13.3 mm²65 A183.91 V (1532.59%)0.0 V303.37 V (2528.06%)45977.8 WDrop/Amp High
4 AWG21.15 mm²85 A115.65 V (963.76%)0.0 V190.77 V (1589.75%)28912.8 WDrop/Amp High
3 AWG26.67 mm²100 A91.71 V (764.29%)0.0 V151.29 V (1260.71%)22928.6 WDrop/Amp High
2 AWG33.62 mm²115 A72.75 V (606.29%)0.0 V120.01 V (1000.1%)18188.7 WDrop/Amp High
1 AWG42.41 mm²130 A57.68 V (480.63%)0.0 V95.14 V (792.81%)14418.9 WDrop/Amp High
1/0 AWG53.49 mm²150 A45.73 V (381.07%)0.0 V75.43 V (628.59%)11432.1 WDrop/Amp High
2/0 AWG67.43 mm²175 A36.27 V (302.29%)0.0 V59.84 V (498.64%)9068.7 WDrop/Amp High
3/0 AWG85.01 mm²200 A28.77 V (239.78%)0.0 V47.46 V (395.52%)7193.3 WDrop/Amp High
4/0 AWG107.2 mm²230 A22.82 V (190.14%)0.0 V37.64 V (313.65%)5704.3 WDrop/Amp High
250 kcmil126.7 mm²255 A19.31 V (160.88%)0.0 V31.85 V (265.38%)4826.4 WDrop/Amp High
300 kcmil152.0 mm²285 A16.09 V (134.1%)0.0 V26.54 V (221.21%)4023.1 WDrop/Amp High
350 kcmil177.3 mm²310 A13.8 V (114.97%)0.0 V22.76 V (189.64%)3449.0 WDrop/Amp High
400 kcmil202.7 mm²335 A12.07 V (100.56%)0.0 V19.91 V (165.88%)3016.8 WDrop/Amp High
500 kcmil253.4 mm²380 A9.65 V (80.44%)2.3 V15.92 V (132.69%)2413.2 WDrop/Amp High
600 kcmil304.0 mm²420 A8.05 V (67.05%)4.0 V13.27 V (110.6%)2011.5 WDrop/Amp High
750 kcmil380.0 mm²475 A6.44 V (53.64%)5.6 V10.62 V (88.48%)1609.2 WDrop/Amp High
1000 kcmil506.7 mm²545 A4.83 V (40.23%)7.2 V7.96 V (66.36%)1206.8 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 250 amps at 750 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 250A load over 750 feet one-way at 12V (DC), you need 14× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.35V (2.87%) and delivers 11.7V at the load.

What size aluminum wire is required for 250 amps at 750 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 7.96V (66.36%).

What breaker size is needed for a 250A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (250A × 1.25 = 312.5A), which corresponds to a standard 350A circuit breaker.