475 Amp Wire Size at 50 Feet (120V Single-Phase (US Standard Branch))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 475 A load over a 50 ft (15.2 m) one-way run.

Copper Wire (≤3% Drop)750 kcmil380.0 mm² · Drop: 0.68%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 1.01V (0.84%)
Voltage at Load End119.2 VLoss: 0.82 V (387.3 W)
Power & Breaker (125%)57.0 kW600A Breaker Recommended

All AWG & kcmil Wire Gauges for 475 Amps at 50 Feet (120V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A148.96 V (124.13%)0.0 V245.71 V (204.76%)70754.3 WDrop/Amp High
12 AWG3.31 mm²20 A93.6 V (78.0%)26.4 V154.4 V (128.67%)44461.9 WDrop/Amp High
10 AWG5.26 mm²30 A58.9 V (49.09%)61.1 V97.16 V (80.97%)27978.9 WDrop/Amp High
8 AWG8.37 mm²50 A37.02 V (30.85%)83.0 V61.06 V (50.88%)17582.9 WDrop/Amp High
6 AWG13.3 mm²65 A23.3 V (19.41%)96.7 V38.43 V (32.02%)11065.3 WDrop/Amp High
4 AWG21.15 mm²85 A14.65 V (12.21%)105.4 V24.16 V (20.14%)6958.3 WDrop/Amp High
3 AWG26.67 mm²100 A11.62 V (9.68%)108.4 V19.16 V (15.97%)5518.1 WDrop/Amp High
2 AWG33.62 mm²115 A9.22 V (7.68%)110.8 V15.2 V (12.67%)4377.4 WDrop/Amp High
1 AWG42.41 mm²130 A7.31 V (6.09%)112.7 V12.05 V (10.04%)3470.1 WDrop/Amp High
1/0 AWG53.49 mm²150 A5.79 V (4.83%)114.2 V9.55 V (7.96%)2751.3 WDrop/Amp High
2/0 AWG67.43 mm²175 A4.59 V (3.83%)115.4 V7.58 V (6.32%)2182.5 WDrop/Amp High
3/0 AWG85.01 mm²200 A3.64 V (3.04%)116.4 V6.01 V (5.01%)1731.2 WDrop/Amp High
4/0 AWG107.2 mm²230 A2.89 V (2.41%)117.1 V4.77 V (3.97%)1372.8 WDrop/Amp High
250 kcmil126.7 mm²255 A2.45 V (2.04%)117.6 V4.03 V (3.36%)1161.6 WDrop/Amp High
300 kcmil152.0 mm²285 A2.04 V (1.7%)118.0 V3.36 V (2.8%)968.2 WDrop/Amp High
350 kcmil177.3 mm²310 A1.75 V (1.46%)118.3 V2.88 V (2.4%)830.1 WDrop/Amp High
400 kcmil202.7 mm²335 A1.53 V (1.27%)118.5 V2.52 V (2.1%)726.0 WDrop/Amp High
500 kcmil253.4 mm²380 A1.22 V (1.02%)118.8 V2.02 V (1.68%)580.8 WDrop/Amp High
600 kcmil304.0 mm²420 A1.02 V (0.85%)119.0 V1.68 V (1.4%)484.1 WDrop/Amp High
750 kcmil380.0 mm²475 A0.82 V (0.68%)119.2 V1.34 V (1.12%)387.3 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.61 V (0.51%)119.4 V1.01 V (0.84%)290.4 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 475 amps at 50 feet (120V)?

To stay within the NEC recommended 3% maximum voltage drop for a 475A load over 50 feet one-way at 120V (1-Phase), you need 750 kcmil copper wire. This produces a voltage drop of 0.82V (0.68%) and delivers 119.2V at the load.

What size aluminum wire is required for 475 amps at 50 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 1.01V (0.84%).

What breaker size is needed for a 475A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (475A × 1.25 = 593.8A), which corresponds to a standard 600A circuit breaker.