🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

500 Amp Wire Size at 800 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 500 A load over a 800 ft (243.8 m) one-way run.

Copper Wire (≤3% Drop)29× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.96%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 16.99V (141.56%)
Voltage at Load End11.6 VLoss: 0.36 V (177.6 W)
Power & Breaker (125%)6.0 kW700A Breaker Recommended

All AWG & kcmil Wire Gauges for 500 Amps at 800 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A2508.74 V (20906.15%)0.0 V4138.25 V (34485.38%)1254369.2 WDrop/Amp High
12 AWG3.31 mm²20 A1576.49 V (13137.4%)0.0 V2600.47 V (21670.57%)788244.1 WDrop/Amp High
10 AWG5.26 mm²30 A992.05 V (8267.07%)0.0 V1636.42 V (13636.81%)496024.3 WDrop/Amp High
8 AWG8.37 mm²50 A623.44 V (5195.32%)0.0 V1028.38 V (8569.84%)311719.0 WDrop/Amp High
6 AWG13.3 mm²65 A392.34 V (3269.53%)0.0 V647.18 V (5393.2%)196172.0 WDrop/Amp High
4 AWG21.15 mm²85 A246.72 V (2056.02%)0.0 V406.98 V (3391.47%)123361.1 WDrop/Amp High
3 AWG26.67 mm²100 A195.66 V (1630.48%)0.0 V322.74 V (2689.52%)97828.6 WDrop/Amp High
2 AWG33.62 mm²115 A155.21 V (1293.42%)0.0 V256.02 V (2133.54%)77605.2 WDrop/Amp High
1 AWG42.41 mm²130 A123.04 V (1025.34%)0.0 V202.96 V (1691.34%)61520.6 WDrop/Amp High
1/0 AWG53.49 mm²150 A97.55 V (812.95%)0.0 V160.92 V (1340.99%)48777.1 WDrop/Amp High
2/0 AWG67.43 mm²175 A77.39 V (644.89%)0.0 V127.65 V (1063.76%)38693.3 WDrop/Amp High
3/0 AWG85.01 mm²200 A61.38 V (511.53%)0.0 V101.25 V (843.78%)30691.5 WDrop/Amp High
4/0 AWG107.2 mm²230 A48.68 V (405.64%)0.0 V80.29 V (669.12%)24338.5 WDrop/Amp High
250 kcmil126.7 mm²255 A41.19 V (343.21%)0.0 V67.94 V (566.14%)20592.6 WDrop/Amp High
300 kcmil152.0 mm²285 A34.33 V (286.08%)0.0 V56.63 V (471.91%)17165.1 WDrop/Amp High
350 kcmil177.3 mm²310 A29.43 V (245.26%)0.0 V48.55 V (404.57%)14715.7 WDrop/Amp High
400 kcmil202.7 mm²335 A25.74 V (214.53%)0.0 V42.46 V (353.87%)12871.7 WDrop/Amp High
500 kcmil253.4 mm²380 A20.59 V (171.61%)0.0 V33.97 V (283.07%)10296.3 WDrop/Amp High
600 kcmil304.0 mm²420 A17.17 V (143.04%)0.0 V28.31 V (235.95%)8582.5 WDrop/Amp High
750 kcmil380.0 mm²475 A13.73 V (114.43%)0.0 V22.65 V (188.76%)6866.0 WDrop/Amp High
1000 kcmil506.7 mm²545 A10.3 V (85.82%)1.7 V16.99 V (141.56%)5149.2 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 500 amps at 800 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 500A load over 800 feet one-way at 12V (DC), you need 29× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.36V (2.96%) and delivers 11.6V at the load.

What size aluminum wire is required for 500 amps at 800 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 16.99V (141.56%).

What breaker size is needed for a 500A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (500A × 1.25 = 625.0A), which corresponds to a standard 700A circuit breaker.