⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

325 Amp Cable Size at 500 Meters (690V Three-Phase (Wind / Heavy Industrial))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 325 A over 500 m (1640.4 ft).

Copper Cable (≤3% Drop)300 mm²Drop: 20.08V (2.91%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 24.84V (3.6%)
Voltage at Load669.9 VLine Loss: 11301.9 W
Max Power & Breaker388.41 kW350A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 325A at 500m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A4015.47 V (581.95%)0.0 V6623.65 V (959.95%)2260375.0 WDrop High
2.5 mm²24 A18 A2409.28 V (349.17%)0.0 V3974.19 V (575.97%)1356225.0 WDrop High
4 mm²32 A25 A1505.8 V (218.23%)0.0 V2483.87 V (359.98%)847640.6 WDrop High
6 mm²41 A32 A1003.87 V (145.49%)0.0 V1655.91 V (239.99%)565093.8 WDrop High
10 mm²57 A44 A602.32 V (87.29%)87.7 V993.55 V (143.99%)339056.2 WDrop High
16 mm²76 A59 A376.45 V (54.56%)313.5 V620.97 V (90.0%)211910.2 WDrop High
25 mm²101 A78 A240.93 V (34.92%)449.1 V397.42 V (57.6%)135622.5 WDrop High
35 mm²125 A97 A172.09 V (24.94%)517.9 V283.87 V (41.14%)96873.2 WDrop High
50 mm²151 A118 A120.46 V (17.46%)569.5 V198.71 V (28.8%)67811.2 WDrop High
70 mm²192 A150 A86.05 V (12.47%)604.0 V141.94 V (20.57%)48436.6 WDrop High
95 mm²232 A181 A63.4 V (9.19%)626.6 V104.58 V (15.16%)35690.1 WDrop High
120 mm²269 A210 A50.19 V (7.27%)639.8 V82.8 V (12.0%)28254.7 WDrop High
150 mm²309 A241 A40.15 V (5.82%)649.8 V66.24 V (9.6%)22603.8 WDrop High
185 mm²353 A275 A32.56 V (4.72%)657.4 V53.71 V (7.78%)18327.4 W~ ≤5%
240 mm²415 A324 A25.1 V (3.64%)664.9 V41.4 V (6.0%)14127.3 W~ ≤5%
300 mm²477 A372 A20.08 V (2.91%)669.9 V33.12 V (4.8%)11301.9 W✓ OK (≤3%)
400 mm²570 A445 A15.06 V (2.18%)674.9 V24.84 V (3.6%)8476.4 W✓ OK (≤3%)

FAQ — 325 Amp Cable Size at 500 Meters (690V Three-Phase (Wind / Heavy Industrial))

What mm² cable size is required for 325A at 500 meters (690V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 300 mm² copper cable for 325A over 500m at 690V (voltage drop: 20.08V or 2.91%).

What is the power capacity of 325A at 690V?

At unity power factor, 325A at 690V supports 388.41 kW with a standard 350A circuit breaker.