⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

25 Amp Wire Size at 275 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 25 A load over a 275 ft (83.8 m) one-way run.

Copper Wire (≤3% Drop)500 kcmil253.4 mm² · Drop: 2.95%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 0.29V (2.43%)
Voltage at Load End11.6 VLoss: 0.35 V (8.8 W)
Power & Breaker (125%)0.3 kW32A Breaker Recommended

All AWG & kcmil Wire Gauges for 25 Amps at 275 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A43.12 V (359.32%)0.0 V71.13 V (592.72%)1078.0 WDrop/Amp High
12 AWG3.31 mm²20 A27.1 V (225.8%)0.0 V44.7 V (372.46%)677.4 WDrop/Amp High
10 AWG5.26 mm²30 A17.05 V (142.09%)0.0 V28.13 V (234.38%)426.3 WDrop/Amp High
8 AWG8.37 mm²50 A10.72 V (89.29%)1.3 V17.68 V (147.29%)267.9 WDrop/Amp High
6 AWG13.3 mm²65 A6.74 V (56.2%)5.3 V11.12 V (92.7%)168.6 WDrop/Amp High
4 AWG21.15 mm²85 A4.24 V (35.34%)7.8 V6.99 V (58.29%)106.0 WDrop/Amp High
3 AWG26.67 mm²100 A3.36 V (28.02%)8.6 V5.55 V (46.23%)84.1 WDrop/Amp High
2 AWG33.62 mm²115 A2.67 V (22.23%)9.3 V4.4 V (36.67%)66.7 WDrop/Amp High
1 AWG42.41 mm²130 A2.11 V (17.62%)9.9 V3.49 V (29.07%)52.9 WDrop/Amp High
1/0 AWG53.49 mm²150 A1.68 V (13.97%)10.3 V2.77 V (23.05%)41.9 WDrop/Amp High
2/0 AWG67.43 mm²175 A1.33 V (11.08%)10.7 V2.19 V (18.28%)33.3 WDrop/Amp High
3/0 AWG85.01 mm²200 A1.06 V (8.79%)10.9 V1.74 V (14.5%)26.4 WDrop/Amp High
4/0 AWG107.2 mm²230 A0.84 V (6.97%)11.2 V1.38 V (11.5%)20.9 WDrop/Amp High
250 kcmil126.7 mm²255 A0.71 V (5.9%)11.3 V1.17 V (9.73%)17.7 WDrop/Amp High
300 kcmil152.0 mm²285 A0.59 V (4.92%)11.4 V0.97 V (8.11%)14.8 W~ ≤5%
350 kcmil177.3 mm²310 A0.51 V (4.22%)11.5 V0.83 V (6.95%)12.6 W~ ≤5%
400 kcmil202.7 mm²335 A0.44 V (3.69%)11.6 V0.73 V (6.08%)11.1 W~ ≤5%
500 kcmil253.4 mm²380 A0.35 V (2.95%)11.6 V0.58 V (4.87%)8.8 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.3 V (2.46%)11.7 V0.49 V (4.06%)7.4 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.24 V (1.97%)11.8 V0.39 V (3.24%)5.9 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.18 V (1.48%)11.8 V0.29 V (2.43%)4.4 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 25 amps at 275 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 25A load over 275 feet one-way at 12V (DC), you need 500 kcmil copper wire. This produces a voltage drop of 0.35V (2.95%) and delivers 11.6V at the load.

What size aluminum wire is required for 25 amps at 275 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 0.29V (2.43%).

What breaker size is needed for a 25A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (25A × 1.25 = 31.2A), which corresponds to a standard 32A circuit breaker.