🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

375 Amp Wire Size at 1000 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 375 A load over a 1000 ft (304.8 m) one-way run.

Copper Wire (≤3% Drop)27× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.98%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 15.93V (132.71%)
Voltage at Load End11.6 VLoss: 0.36 V (134.1 W)
Power & Breaker (125%)4.5 kW500A Breaker Recommended

All AWG & kcmil Wire Gauges for 375 Amps at 1000 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A2351.94 V (19599.52%)0.0 V3879.61 V (32330.05%)881978.4 WDrop/Amp High
12 AWG3.31 mm²20 A1477.96 V (12316.31%)0.0 V2437.94 V (20316.16%)554234.1 WDrop/Amp High
10 AWG5.26 mm²30 A930.05 V (7750.38%)0.0 V1534.14 V (12784.51%)348767.1 WDrop/Amp High
8 AWG8.37 mm²50 A584.47 V (4870.61%)0.0 V964.11 V (8034.23%)219177.4 WDrop/Amp High
6 AWG13.3 mm²65 A367.82 V (3065.19%)0.0 V606.74 V (5056.13%)137933.5 WDrop/Amp High
4 AWG21.15 mm²85 A231.3 V (1927.52%)0.0 V381.54 V (3179.5%)86738.3 WDrop/Amp High
3 AWG26.67 mm²100 A183.43 V (1528.57%)0.0 V302.57 V (2521.43%)68785.7 WDrop/Amp High
2 AWG33.62 mm²115 A145.51 V (1212.58%)0.0 V240.02 V (2000.19%)54566.2 WDrop/Amp High
1 AWG42.41 mm²130 A115.35 V (961.26%)0.0 V190.28 V (1585.63%)43256.7 WDrop/Amp High
1/0 AWG53.49 mm²150 A91.46 V (762.14%)0.0 V150.86 V (1257.18%)34296.4 WDrop/Amp High
2/0 AWG67.43 mm²175 A72.55 V (604.58%)0.0 V119.67 V (997.28%)27206.2 WDrop/Amp High
3/0 AWG85.01 mm²200 A57.55 V (479.56%)0.0 V94.93 V (791.04%)21580.0 WDrop/Amp High
4/0 AWG107.2 mm²230 A45.63 V (380.29%)0.0 V75.28 V (627.3%)17113.0 WDrop/Amp High
250 kcmil126.7 mm²255 A38.61 V (321.76%)0.0 V63.69 V (530.75%)14479.2 WDrop/Amp High
300 kcmil152.0 mm²285 A32.18 V (268.2%)0.0 V53.09 V (442.41%)12069.2 WDrop/Amp High
350 kcmil177.3 mm²310 A27.59 V (229.93%)0.0 V45.51 V (379.28%)10347.0 WDrop/Amp High
400 kcmil202.7 mm²335 A24.13 V (201.12%)0.0 V39.81 V (331.75%)9050.4 WDrop/Amp High
500 kcmil253.4 mm²380 A19.31 V (160.88%)0.0 V31.85 V (265.38%)7239.6 WDrop/Amp High
600 kcmil304.0 mm²420 A16.09 V (134.1%)0.0 V26.54 V (221.21%)6034.6 WDrop/Amp High
750 kcmil380.0 mm²475 A12.87 V (107.28%)0.0 V21.24 V (176.96%)4827.7 WDrop/Amp High
1000 kcmil506.7 mm²545 A9.65 V (80.46%)2.3 V15.93 V (132.71%)3620.5 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 375 amps at 1000 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 375A load over 1000 feet one-way at 12V (DC), you need 27× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.36V (2.98%) and delivers 11.6V at the load.

What size aluminum wire is required for 375 amps at 1000 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 15.93V (132.71%).

What breaker size is needed for a 375A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (375A × 1.25 = 468.8A), which corresponds to a standard 500A circuit breaker.