⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

5 Amp Wire Size at 350 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 5 A load over a 350 ft (106.7 m) one-way run.

Copper Wire (≤3% Drop)2/0 AWG67.43 mm² · Drop: 2.82%
Aluminum Wire (≤3% Drop)4/0 AWGDrop: 0.35V (2.93%)
Voltage at Load End11.7 VLoss: 0.34 V (1.7 W)
Power & Breaker (125%)0.06 kW10A Breaker Recommended

All AWG & kcmil Wire Gauges for 5 Amps at 350 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A10.98 V (91.46%)1.0 V18.1 V (150.87%)54.9 WDrop/Amp High
12 AWG3.31 mm²20 A6.9 V (57.48%)5.1 V11.38 V (94.81%)34.5 WDrop/Amp High
10 AWG5.26 mm²30 A4.34 V (36.17%)7.7 V7.16 V (59.66%)21.7 WDrop/Amp High
8 AWG8.37 mm²50 A2.73 V (22.73%)9.3 V4.5 V (37.49%)13.6 WDrop/Amp High
6 AWG13.3 mm²65 A1.72 V (14.3%)10.3 V2.83 V (23.6%)8.6 WDrop/Amp High
4 AWG21.15 mm²85 A1.08 V (9.0%)10.9 V1.78 V (14.84%)5.4 WDrop/Amp High
3 AWG26.67 mm²100 A0.86 V (7.13%)11.1 V1.41 V (11.77%)4.3 WDrop/Amp High
2 AWG33.62 mm²115 A0.68 V (5.66%)11.3 V1.12 V (9.33%)3.4 WDrop/Amp High
1 AWG42.41 mm²130 A0.54 V (4.49%)11.5 V0.89 V (7.4%)2.7 W~ ≤5%
1/0 AWG53.49 mm²150 A0.43 V (3.56%)11.6 V0.7 V (5.87%)2.1 W~ ≤5%
2/0 AWG67.43 mm²175 A0.34 V (2.82%)11.7 V0.56 V (4.65%)1.7 W✓ PASS (≤3%)
3/0 AWG85.01 mm²200 A0.27 V (2.24%)11.7 V0.44 V (3.69%)1.3 W✓ PASS (≤3%)
4/0 AWG107.2 mm²230 A0.21 V (1.77%)11.8 V0.35 V (2.93%)1.1 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.18 V (1.5%)11.8 V0.3 V (2.48%)0.9 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.15 V (1.25%)11.8 V0.25 V (2.06%)0.8 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.13 V (1.07%)11.9 V0.21 V (1.77%)0.6 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.11 V (0.94%)11.9 V0.19 V (1.55%)0.6 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.09 V (0.75%)11.9 V0.15 V (1.24%)0.5 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.08 V (0.63%)11.9 V0.12 V (1.03%)0.4 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.06 V (0.5%)11.9 V0.1 V (0.83%)0.3 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.05 V (0.38%)12.0 V0.07 V (0.62%)0.2 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 5 amps at 350 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 5A load over 350 feet one-way at 12V (DC), you need 2/0 AWG copper wire. This produces a voltage drop of 0.34V (2.82%) and delivers 11.7V at the load.

What size aluminum wire is required for 5 amps at 350 feet?

Using aluminum conductors (75°C rating), you should use 4/0 AWG to maintain voltage drop at 0.35V (2.93%).

What breaker size is needed for a 5A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (5A × 1.25 = 6.2A), which corresponds to a standard 10A circuit breaker.