650 Amp Wire Size at 275 Feet (120V Single-Phase (US Standard Branch))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 650 A load over a 275 ft (83.8 m) one-way run.

Copper Wire (≤3% Drop)2× 1000 kcmil (Parallel)506.7 mm² · Drop: 1.92%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 7.59V (6.33%)
Voltage at Load End117.7 VLoss: 2.3 V (1495.7 W)
Power & Breaker (125%)78.0 kW1000A Breaker Recommended

All AWG & kcmil Wire Gauges for 650 Amps at 275 Feet (120V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A1121.09 V (934.24%)0.0 V1849.28 V (1541.07%)728710.1 WDrop/Amp High
12 AWG3.31 mm²20 A704.49 V (587.08%)0.0 V1162.08 V (968.4%)457920.6 WDrop/Amp High
10 AWG5.26 mm²30 A443.32 V (369.43%)0.0 V731.27 V (609.39%)288159.1 WDrop/Amp High
8 AWG8.37 mm²50 A278.6 V (232.17%)0.0 V459.56 V (382.96%)181089.3 WDrop/Amp High
6 AWG13.3 mm²65 A175.33 V (146.11%)0.0 V289.21 V (241.01%)113963.7 WDrop/Amp High
4 AWG21.15 mm²85 A110.25 V (91.88%)9.7 V181.87 V (151.56%)71665.1 WDrop/Amp High
3 AWG26.67 mm²100 A87.43 V (72.86%)32.6 V144.23 V (120.19%)56832.3 WDrop/Amp High
2 AWG33.62 mm²115 A69.36 V (57.8%)50.6 V114.41 V (95.34%)45083.8 WDrop/Amp High
1 AWG42.41 mm²130 A54.98 V (45.82%)65.0 V90.7 V (75.58%)35739.6 WDrop/Amp High
1/0 AWG53.49 mm²150 A43.59 V (36.33%)76.4 V71.91 V (59.93%)28336.5 WDrop/Amp High
2/0 AWG67.43 mm²175 A34.58 V (28.82%)85.4 V57.04 V (47.54%)22478.4 WDrop/Amp High
3/0 AWG85.01 mm²200 A27.43 V (22.86%)92.6 V45.25 V (37.71%)17829.9 WDrop/Amp High
4/0 AWG107.2 mm²230 A21.75 V (18.13%)98.2 V35.88 V (29.9%)14139.2 WDrop/Amp High
250 kcmil126.7 mm²255 A18.4 V (15.34%)101.6 V30.36 V (25.3%)11963.0 WDrop/Amp High
300 kcmil152.0 mm²285 A15.34 V (12.78%)104.7 V25.31 V (21.09%)9971.8 WDrop/Amp High
350 kcmil177.3 mm²310 A13.15 V (10.96%)106.8 V21.69 V (18.08%)8548.9 WDrop/Amp High
400 kcmil202.7 mm²335 A11.5 V (9.59%)108.5 V18.98 V (15.81%)7477.6 WDrop/Amp High
500 kcmil253.4 mm²380 A9.2 V (7.67%)110.8 V15.18 V (12.65%)5981.5 WDrop/Amp High
600 kcmil304.0 mm²420 A7.67 V (6.39%)112.3 V12.65 V (10.54%)4985.9 WDrop/Amp High
750 kcmil380.0 mm²475 A6.14 V (5.11%)113.9 V10.12 V (8.44%)3988.7 WDrop/Amp High
1000 kcmil506.7 mm²545 A4.6 V (3.84%)115.4 V7.59 V (6.33%)2991.4 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 650 amps at 275 feet (120V)?

To stay within the NEC recommended 3% maximum voltage drop for a 650A load over 275 feet one-way at 120V (1-Phase), you need 2× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 2.3V (1.92%) and delivers 117.7V at the load.

What size aluminum wire is required for 650 amps at 275 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 7.59V (6.33%).

What breaker size is needed for a 650A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (650A × 1.25 = 812.5A), which corresponds to a standard 1000A circuit breaker.