10 Amp Wire Size at 600 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 10 A load over a 600 ft (182.9 m) one-way run.

Copper Wire (≤3% Drop)500 kcmil253.4 mm² · Drop: 2.57%
Aluminum Wire (≤3% Drop)750 kcmilDrop: 0.34V (2.83%)
Voltage at Load End11.7 VLoss: 0.31 V (3.1 W)
Power & Breaker (125%)0.12 kW13A Breaker Recommended

All AWG & kcmil Wire Gauges for 10 Amps at 600 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A37.63 V (313.59%)0.0 V62.07 V (517.28%)376.3 WDrop/Amp High
12 AWG3.31 mm²20 A23.65 V (197.06%)0.0 V39.01 V (325.06%)236.5 WDrop/Amp High
10 AWG5.26 mm²30 A14.88 V (124.01%)0.0 V24.55 V (204.55%)148.8 WDrop/Amp High
8 AWG8.37 mm²50 A9.35 V (77.93%)2.6 V15.43 V (128.55%)93.5 WDrop/Amp High
6 AWG13.3 mm²65 A5.89 V (49.04%)6.1 V9.71 V (80.9%)58.9 WDrop/Amp High
4 AWG21.15 mm²85 A3.7 V (30.84%)8.3 V6.1 V (50.87%)37.0 WDrop/Amp High
3 AWG26.67 mm²100 A2.93 V (24.46%)9.1 V4.84 V (40.34%)29.3 WDrop/Amp High
2 AWG33.62 mm²115 A2.33 V (19.4%)9.7 V3.84 V (32.0%)23.3 WDrop/Amp High
1 AWG42.41 mm²130 A1.85 V (15.38%)10.2 V3.04 V (25.37%)18.5 WDrop/Amp High
1/0 AWG53.49 mm²150 A1.46 V (12.19%)10.5 V2.41 V (20.11%)14.6 WDrop/Amp High
2/0 AWG67.43 mm²175 A1.16 V (9.67%)10.8 V1.91 V (15.96%)11.6 WDrop/Amp High
3/0 AWG85.01 mm²200 A0.92 V (7.67%)11.1 V1.52 V (12.66%)9.2 WDrop/Amp High
4/0 AWG107.2 mm²230 A0.73 V (6.08%)11.3 V1.2 V (10.04%)7.3 WDrop/Amp High
250 kcmil126.7 mm²255 A0.62 V (5.15%)11.4 V1.02 V (8.49%)6.2 WDrop/Amp High
300 kcmil152.0 mm²285 A0.51 V (4.29%)11.5 V0.85 V (7.08%)5.1 W~ ≤5%
350 kcmil177.3 mm²310 A0.44 V (3.68%)11.6 V0.73 V (6.07%)4.4 W~ ≤5%
400 kcmil202.7 mm²335 A0.39 V (3.22%)11.6 V0.64 V (5.31%)3.9 W~ ≤5%
500 kcmil253.4 mm²380 A0.31 V (2.57%)11.7 V0.51 V (4.25%)3.1 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.26 V (2.15%)11.7 V0.42 V (3.54%)2.6 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.21 V (1.72%)11.8 V0.34 V (2.83%)2.1 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.15 V (1.29%)11.8 V0.25 V (2.12%)1.5 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 10 amps at 600 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 10A load over 600 feet one-way at 12V (DC), you need 500 kcmil copper wire. This produces a voltage drop of 0.31V (2.57%) and delivers 11.7V at the load.

What size aluminum wire is required for 10 amps at 600 feet?

Using aluminum conductors (75°C rating), you should use 750 kcmil to maintain voltage drop at 0.34V (2.83%).

What breaker size is needed for a 10A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (10A × 1.25 = 12.5A), which corresponds to a standard 13A circuit breaker.